AT49BV162A ATMEL Corporation, AT49BV162A Datasheet - Page 8

no-image

AT49BV162A

Manufacturer Part Number
AT49BV162A
Description
16-megabit (1M x 16/2M x 8) 3-volt Only Flash Memory
Manufacturer
ATMEL Corporation
Datasheets

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT49BV162A
Manufacturer:
AT
Quantity:
8
Part Number:
AT49BV162A
Manufacturer:
ATMEL
Quantity:
50 000
Part Number:
AT49BV162A-70CI
Manufacturer:
ATMEL
Quantity:
1 120
Part Number:
AT49BV162A-70CI
Manufacturer:
Atmel
Quantity:
10 000
Company:
Part Number:
AT49BV162A-70CI
Quantity:
409
Part Number:
AT49BV162A-70CU
Manufacturer:
PHILIPS
Quantity:
5
Part Number:
AT49BV162A-70CU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT49BV162A-70TI
Manufacturer:
ATMEL
Quantity:
5 530
Part Number:
AT49BV162A-70TU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT49BV162AT-70CI
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT49BV162AT-70CU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT49BV162AT-70TI
Manufacturer:
ATMEL
Quantity:
1 000
8
AT49BV162/163A(T)
nection allows for OR-tying of several devices to the same RDY/BUSY line. Please see
“Status Bit Table” on page 11 for more details.
CFI: Common Flash Interface (CFI) is a published, standardized data structure that may be
read from a flash device. CFI allows system software to query the installed device to deter-
mine the configurations, various electrical and timing parameters, and functions supported by
the device. CFI is used to allow the system to learn how to interface to the flash device most
optimally. The two primary benefits of using CFI are ease of upgrading and second source
availability. The command to enter the CFI Query mode is a one-bus cycle command which
requires writing data 98h to address 55h. The CFI Query command can be written when the
device is ready to read data or can also be written when the part is in the product ID mode.
Once in the CFI Query mode, the system can read CFI data at the addresses given in Table 1
on page 24. To exit the CFI Query mode, the product ID exit command must be given.
HARDWARE DATA PROTECTION: The Hardware Data Protection feature protects against
inadvertent programs to the AT49BV162A(T)/163A(T) in the following ways: (a) V
V
V
before programming. (c) Program inhibit: holding any one of OE low, CE high or WE high
inhibits program cycles. (d) Program inhibit: V
once V
INPUT LEVELS: While operating with a 2.65V to 3.6V power supply, the address inputs and
control inputs (OE, CE and WE) may be driven from 0 to 5.5V without adversely affecting the
operation of the device. The I/O lines can only be driven from 0 to V
CC
CC
is below 1.8V (typical), the program function is inhibited. (b) V
has reached the V
PP
has reached 1.65V, program and erase operations are inhibited for 100 ns.
CC
sense level, the device will automatically time out 10 ms (typical)
PP
is less than V
ILPP
CC
. (e) V
CC
+ 0.6V.
power-on delay: once
PP
power-on delay:
3349G–FLASH–7/04
CC
sense: if