M28W640 STMicroelectronics, M28W640 Datasheet - Page 13

no-image

M28W640

Manufacturer Part Number
M28W640
Description
64 Mbit 4Mb x16/ Boot Block 3V Supply Flash Memory
Manufacturer
STMicroelectronics
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M28W640
Manufacturer:
ST
Quantity:
5 967
Part Number:
M28W640
Quantity:
23
Part Number:
M28W640
Manufacturer:
ST
0
Part Number:
M28W640-ECT70ZB6
Manufacturer:
ST
Quantity:
7
Part Number:
M28W640CB-90N6
Manufacturer:
ST
0
Part Number:
M28W640CB90N6
Manufacturer:
ST
Quantity:
645
Part Number:
M28W640CB90N6
Manufacturer:
ST
0
Part Number:
M28W640CM90N6
Manufacturer:
ST
0
Part Number:
M28W640CT
Manufacturer:
ST
0
Part Number:
M28W640DB70N6
Manufacturer:
ST
Quantity:
188
Part Number:
M28W640EC70N6/DB70N6
Manufacturer:
ST
Quantity:
20 000
quent Bus Read operations read the Status Reg-
ister.
See Appendix C, Figure 20, Program Suspend &
Resume Flowchart and Pseudo Code, and Figure
22, Erase Suspend & Resume Flowchart and
Pseudo Code for flowcharts for using the Program/
Erase Resume command.
Protection Register Program Command
The Protection Register Program command is
used to Program the 128 bit user One-Time-Pro-
grammable (OTP) segment of the Protection Reg-
ister. The segment is programmed 16 bits at a
time. When shipped all bits in the segment are set
to ‘1’. The user can only program the bits to ‘0’.
Two write cycles are required to issue the Protec-
tion Register Program command.
Read operations output the Status Register con-
tent after the programming has started.
The segment can be protected by programming bit
1 of the Protection Lock Register. Bit 1 of the Pro-
tection Lock Register protects bit 2 of the Protec-
tion Lock Register. Programming bit 2 of the
Protection Lock Register will result in a permanent
protection of the Security Block (see Figure 6, Se-
curity Block Memory Map). Attempting to program
a previously protected Protection Register will re-
sult in a Status Register error. The protection of
the Protection Register and/or the Security Block
is not reversible.
The Protection Register Program cannot be sus-
pended.
Block Lock Command
The Block Lock command is used to lock a block
and prevent Program or Erase operations from
changing the data in it. All blocks are locked at
power-up or reset.
Two Bus Write cycles are required to issue the
Block Lock command.
The first bus cycle sets up the Protection
Register Program command.
The second latches the Address and the Data to
be written to the Protection Register and starts
the Program/Erase Controller.
The first bus cycle sets up the Block Lock
command.
The lock status can be monitored for each block
using the Read Electronic Signature command.
Table. 9 shows the protection status after issuing
a Block Lock command.
The Block Lock bits are volatile, once set they re-
main set until a hardware reset or power-down/
power-up. They are cleared by a Blocks Unlock
command. Refer to the section, Block Locking, for
a detailed explanation.
Block Unlock Command
The Blocks Unlock command is used to unlock a
block, allowing the block to be programmed or
erased. Two Bus Write cycles are required to is-
sue the Blocks Unlock command.
The lock status can be monitored for each block
using the Read Electronic Signature command.
Table. 9 shows the protection status after issuing
a Block Unlock command. Refer to the section,
Block Locking, for a detailed explanation.
Block Lock-Down Command
A locked block cannot be Programmed or Erased,
or have its protection status changed when WP is
low, V
function is disabled and the locked blocks can be
individually unlocked by the Block Unlock com-
mand.
Two Bus Write cycles are required to issue the
Block Lock-Down command.
The lock status can be monitored for each block
using the Read Electronic Signature command.
Locked-Down blocks revert to the locked (and not
locked-down) state when the device is reset on
power-down. Table. 9 shows the protection status
after issuing a Block Lock-Down command. Refer
to the section, Block Locking, for a detailed expla-
nation.
The second Bus Write cycle latches the block
address.
The first bus cycle sets up the Block Unlock
command.
The second Bus Write cycle latches the block
address.
The first bus cycle sets up the Block Lock
command.
The second Bus Write cycle latches the block
address.
IL
. When WP is high, V
M28W640CT, M28W640CB
IH,
the Lock-Down
13/54