HYS64D16000 Infineon, HYS64D16000 Datasheet - Page 18

no-image

HYS64D16000

Manufacturer Part Number
HYS64D16000
Description
200-Pin Small Outline Dual-In-Line Memory Modules
Manufacturer
Infineon
Datasheet
Table 9
Parameter
Auto-refresh to Active/Auto-refresh command period
Active to Read or Write delay
Precharge command period
Active to Autoprecharge delay
Active bank A to Active bank B command
Write recovery time
Auto precharge write recovery + precharge time
Internal write to read command delay
Exit self-refresh to non-read command
Exit self-refresh to read command
Average Periodic Refresh Interval
1) 0 C
2) Input slew rate
3) The CK/CK input reference level (for timing reference to CK/CK) is the point at which CK and CK cross: the input reference
4) Inputs are not recognized as valid until
5) The Output timing reference level, as measured at the timing reference point indicated in AC Characteristics (note 3) is
6) These parameters guarantee device timing, but they are not necessarily tested on each device.
7)
8) The specific requirement is that DQS be valid (HIGH, LOW, or some point on a valid transition) on or before this CK edge.
9) The maximum limit for this parameter is not a device limit. The device operates with a greater value for this parameter, but
10) Fast slew rate
11) For each of the terms, if not already an integer, round to the next highest integer.
12) A maximum of eight Autorefresh commands can be posted to any given DDR SDRAM device.
Data Sheet
level for signals other than CK/CK, is
t
to a specific voltage level, but specify when the device is no longer driving (HZ), or begins driving (LZ).
A valid transition is defined as monotonic and meeting the input slew rate specifications of the device. When no writes were
previously in progress on the bus, DQS will be transitioning from Hi-Z to logic LOW. If a previous write was in progress,
DQS could be HIGH, LOW, or transitioning from HIGH to LOW at this time, depending on
system performance (bus turnaround) degrades accordingly.
ns, measured between
cycle time.
HZ
and
T
t
A
LZ
AC Timing - Absolute Specifications –6
transitions occur in the same access time windows as valid data transitions. These parameters are not referred
70 C
1.0 V/ns , slow slew rate
1 V/ns
; V
DDQ
V
OH(ac)
= 2.5 V
and
0.2 V,
V
V
OL(ac)
REF
V
REF
V
. CK/CK slew rate are
.
DD
0.5 V/ns and < 1 V/ns for command/address and CK & CK slew rate > 1.0 V/
stabilizes.
= +2.5 V
18
0.2 V
Symbol
t
t
t
t
t
t
t
t
t
t
t
RFC
RCD
RP
RAP
RRD
WR
DAL
WTR
XSNR
XSRD
REFI
1.0 V/ns.
Small Outline DDR SDRAM Modules
Min.
72
18
18
18
12
15
1
75
200
HYS64D[32020/16000]HDL–6–C
DDR333
t
–6
CK
Max.
7.8
is equal to the actual system clock
t
DQSS
Electrical Characteristics
Unit Note/ Test
ns
ns
ns
ns
ns
ns
t
t
ns
t
CK
CK
CK
s
.
Rev. 0.5, 2003-08
Condition
2)3)4)5)
2)3)4)5)
2)3)4)5)
2)3)4)5)
2)3)4)5)
2)3)4)5)
2)3)4)5)11)
2)3)4)5)
2)3)4)5)
2)3)4)5)
2)3)4)5)12)
1)
V
TT
.

Related parts for HYS64D16000