XE0092LCC ETC1 [List of Unclassifed Manufacturers], XE0092LCC Datasheet - Page 11

no-image

XE0092LCC

Manufacturer Part Number
XE0092LCC
Description
Surface-Mount DAA Modules for Audio or Data Transfer
Manufacturer
ETC1 [List of Unclassifed Manufacturers]
Datasheet
An asterisk indicates the factory default
AT COMMANDS
A
Dn Initiate a Wireless Link - attempt to
En Echo Characters -
In
Qn Result Code Display -
Sn= Set Value of Register Sn
Sn? Read Value of Register Sn
Vn Response Type -
Zn
&F Restore
&IAn? Read Local Analog Input “n” - allows
XECOM
Answer Command - force response to a link
request
connect with the transceiver at address n.
n=0 Characters not Echoed
n=1 Characters Echoed *
Product Identification -
n=0 Display Product Code
n=1 Display Product Name
n=2 Display Model Number
n=3 Display Copyright
n=4 Display Firmware Revision
n=0 Display Result Codes *
n=1 Do not Display Result Codes
n=0 Numeric Responses
n=1 Full Word Responses *
Reset - executes a soft Reset
n=0 Reset to Values in User Profile 0 *
n=1 Reset to Values in User Profile 1
commands and registers to default values.
the host to read local analog inputs.
n=0 Read input ADC0
n=1 Read input ADC1
Factory
Settings
-
return
(11)
&IDn? Read Local Digital Input “n” - read the
&Kn Flow Control - selects the flow control used
&V View Active Configuration - sends the
&Wn Store Current Configuration - loads the
# B Wireless Broadcast - initiates wireless
#C Count-Off Request (ASCII) - Initiates a
#E: Count-Off Response (ASCII) - Programs
#E= Count-Off Response (Hex) - Programs the
&IDn=z Set Local Digital Output “n” - sets
status of the local digital inputs.
n=0 Read input DIO0
n=1 Read input DIO1
n=2 Read input DIO2
n=3 Read input DIO3
n=4 Read DIO4 (ADC0 set as digital I/O)
n=5 Read DIO5 (ADC1 set as digital I/O)
the state of the local digital outputs. z=0 sets
the output to a logic low; z=1 to a logic high.
n=0 Set output DIO0
n=1 Set output DIO1
n=2 Set output DIO2
n=3 Set output DIO3
between the system host and the XE24S500
n=0 Flow Control Disabled
n=3 RTS/CTS, hardware Flow Control
n=4 XON/XOFF, in-band Flow Control
active configuration data to the system host.
current configuration into User Profile 0 or 1.
n=0 load configuration into User Profile 0
n=1 load configuration into User Profile 1
broadcast for diagnostic purposes.
“Count-off’ sequence. Status report in ASCII.
the 8 byte ASCII “Count-off” status message.
8 byte “Count-off” response in hex format.
XE24S500