Tunable Loop
Table 2 .General recommended values of R
combinations.
Table 3 .Recommended values of R
with Vin=12V.
Thermal Considerations
Power modules operate in a variety of thermal environments; however, sufficient cooling should always be
provided to help ensure reliable operation.
Considerations include ambient temperature, airflow, module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of the module will result in an increase in reliability. The
thermal data presented here is based on physical measurements taken in a wind tunnel. The test set-up is
shown below.
November 5, 2009
R
C
R
C
Co
Vo
Δ V
TUNE
TUNE
Co
NON-ISOLATED DC/DC CONVERTERS
4.5 Vdc - 14 Vdc Input, 0.69 Vdc - 5.5 Vdc /12 A Outputs
TUNE
TUNE
4x47μF
3300pF
1x47μF
1000pF
91mV
270
5V
470
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 •
TM
1x47μF + 330μF
(Continued)
3300pF
2x47μF
Polymer
4700pF
270
60mV
3.3V
220
Wind Tunnel
4x47μF
4700pF
TUNE
150
PWBs
2x47μF + 330μF
and C
Polymer
6800pF
TUNE
47mV
2.5V
10x47μF 20x47μF
220
8200pF
TUNE to
Thermal Test Setup
150
and C
Bel Power, Inc. , a subsidiary of Bel Fuse, Inc.
obtain transient deviation of ≤2% of Vout for a 6A step load
TUNE for
flow
Air
(0.50)
x
12.7_
6x47μF + 330μF
12nF
150
(3.0)
76.2_
25.4_
(1.0)
Vin=12V and various external ceramic capacitor
Polymer
35mV
18nF
1.8V
220
Probe Location
for measuring
airflow and
ambient
temperature
Power Module
6x47μF + 2x330μF
Polymer
23mV
33nF
1.2V
150
4x47μF + 6x330μF
www.belfuse.com
Polymer
100nF
0.69V
12mV
150
20