EDD10163BBH-5BLS-F ELPIDA [Elpida Memory], EDD10163BBH-5BLS-F Datasheet - Page 27

no-image

EDD10163BBH-5BLS-F

Manufacturer Part Number
EDD10163BBH-5BLS-F
Description
Manufacturer
ELPIDA [Elpida Memory]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EDD10163BBH-5BLS-F
Manufacturer:
ELPIDA
Quantity:
17 580
Read/Write Operations
Bank Active
A read or a write operation begins with the bank active command [ACT]. The bank active command determines a
bank address and a row address. For the bank and the row, a read or a write command can be issued tRCD after
the ACT is issued.
Read Operation
The burst length (BL), the /CAS latency (CL) and the burst type (BT) of the mode register are referred when a read
command is issued. The burst length (BL) determines the length of a sequential output data by the read command
that can be set to 2, 4, 8 or 16. The starting address of the burst read is defined by the column address, the bank
select address (See “Pin Function”) in the cycle when the read command is issued. The data output timing is
characterized by CL and tAC. The read burst start (CL-1)
command is latched. The DDR Mobile RAM outputs the data strobe through DQS pins simultaneously with data.
tRPRE prior to the first rising edge of the data strobe, the DQS pins are driven low from high-Z state. This low period
of DQS is referred as read preamble. The burst data are output coincidentally at both the rising and falling edge of
the data strobe. The DQ pins become high-Z in the next cycle after the burst read operation completed. tRPST from
the last falling edge of the data strobe, the DQS pins become high-Z. This low period of DQS is referred as read
postamble.
Preliminary Data Sheet E1436E30 (Ver. 3.0)
Command
DQS
DQ
Address
/CK
CK
NOP
Row
ACT
BL = 16
BL = 2
BL = 4
BL = 8
tRCD
NOP
Column
READ
Read Operation (Burst Length)
tRPRE
27
tCK + tAC (ns) after the clock rising edge where the read
out0 out1
out0 out1 out2 out3
out0 out1 out2 out3 out4 out5 out6 out7
out0 out1 out2 out3 out4 out5 out6 out7
NOP
tRPST
EDD10163BBH-LS
CL = 3
BL: Burst length
out
14
out
15

Related parts for EDD10163BBH-5BLS-F