Description
SPECIFICATIONS FOR LCD MODULE
Manufacturer
ZETTLER [ZETTLER Electronics]
Datasheet
A
M
P
I R E
SPECIFICATIONS FOR
LCD MODULE
CUSTOMER
CUSTOMER PART NO.
AMPIRE PART NO.
AT-320240Q5FIQW-T76H(V)(R)
APPROVED BY
DATE
APPROVED BY
CHECKED BY
ORGANIZED BY
Date : 2006/9/12
AMPIRE CO., LTD.
1

Related parts for AT-320240Q5FIQW

AT-320240Q5FIQW Summary of contents

Page 1

... SPECIFICATIONS FOR LCD MODULE CUSTOMER CUSTOMER PART NO. AMPIRE PART NO. APPROVED BY DATE APPROVED BY Date : 2006/9/12 AT-320240Q5FIQW-T76H(V)(R) CHECKED BY AMPIRE CO., LTD. ORGANIZED BY 1 ...

Page 2

... RECORD OF REVISION Revision Date 2006/8/8 New Release 2006/9/12 Modify Mechanical data Date : 2006/9/12 Contents AMPIRE CO., LTD. Editor Lorry Tony 2 ...

Page 3

... Module size (w/ Touch panel) 3 ABSOLUTE MAXIMUM RATINGS Parameter Logic Circuit Supply Voltage LCD Driving Voltage Input Voltage Operating Temp. Extended temp. type Storage Temp. Date : 2006/9/12 240 dot- matrix, 1/240 duty. Stand Value 0.225(W) 0.225(H) 0.24(W) 0.24(H) 62.0 (W) 81.8 (H) 73.0(W) 93.3(H) 6.7 max (T) 73.0(W) 93.3(H) 8.6 max (T) Symbol Min VDD-VSS -0 ...

Page 4

... Parameter Symbol Forward Current IF LCM Luminous intensity Forward Voltage VF LED C.I (NOTE 4): Luminous intensity is decided by forward current of White LED. (NOTE 5): White LEDs are with voltage tolerance (NOTE 6): White LEDs are with color tolerance Date : 2006/9/12 Condition Min Typ ----- Electronic Characteristics ----- 2 22.7 23.9 -20 C 20.7 21 ...

Page 5

... LED Dice number = 4 Please keep the IF between 60~80mA Luminous intensity is decided by IF (NOTE 1) Contrast ratio : CR = (Brightness in OFF state) / (Brightness in ON state) ( NOTE 2 ) Response time : (NOTE 3) Viewing angle Date : 2006/9/ AMPIRE CO., LTD. 5 ...

Page 6

... Touch Panel Electrical Specification Parameter ON Resistance Insulating Resistance Chattering 5 BLOCK DIAGRAM From MPU /RESET /RD Controller /WR RA8835 /CS A0 DB0~7 SRAM * Please use the YDIS pin and the inner command of the RA8835 to control Display On/Off. Date : 2006/9/12 Specification 400 ~ 800 260 ~ 600 More than 10M ...

Page 7

... No Connection Serial Clock - Touch Panel Left Signal in X Axis Serial Data Output - Touch Panel Right Signal in X Axis Serial Data Input - Touch Panel Upper Signal in Y Axis T/P controller Chip Select. Active Low - Touch Panel Lower Signal in X Axis - Pen Interrupt ...

Page 8

... Data Hold Time /RD Access Time Output Disable Time Note: For memory control and system control commands: tCYC8=2tC+tOC+tCEA+75 > tACV +245 For all other commands: tCYC8=4tC+tOC+30 A0,/CS /WR,/RD DB0~DB7 (Write) DB0~DB7 (Read) Date : 2006/9/12 Condition Symbol tAH8 tAW8 tCYC CL=100 pF tOC VDD=2.7~4.5 tDS8 tDH8 tACC8 tOH8 AMPIRE CO ...

Page 9

... Access Time Enable Pulse Width Note: For memory control and system control commands: tCYC6=2tC+tEW+tCEA+75 > tACV +245 For all other commands: tCYC6=4tC+tEW+30 E R/W A0, /CS DB0~DB7 (Write) DB0~DB7 (Read) Date : 2006/9/12 Condition Symbol tCYC6 tAW6 tAH6 CL=100 pF tDS6 VDD=2.7~4.5 tDH6 tOH6 tACC6 tEW AC Electrical Characteristics AMPIRE CO ...

Page 10

... CSRW, CSRR: Each byte is processed individually. The microprocessor may read or write just the low byte of the cursor address ...

Page 11

... INNER DATA FORMAT COM1 # #320 D0 Date : 2006/9/ Portrait Display Type (Top View) AMPIRE CO., LTD. COM240 ...

Page 12

... Regardless Portrait or Landscape type, both are 1/240 duty. The only difference is the opposite scan direction on Common driver. The character mode of RA8835 could only be used on Landscape type. The character will be Mirrored on Portrait type. 10 JUMPER SETTING Item Display Type Portrait (default) MPU 80 family (default) Date : 2006/9/ Landscape Display Type(Top View) Option Jumper Setting Pin 1,2 short on JP1& ...

Page 13

... ACCEPTABLE QUALITY LEVEL A major defect is defined as one that could cause failure to or materially reduce the usability of the unit for its intended purpose. A minor defect is one that does not materially reduce the usability of the unit for its intended purpose infringement from established standards and has no significant bearing on its effective use or operation ...

Page 14

... INSPECTION QUALITY CRITERIA Item Description of defects Function Short circuit or Pattern cut Dimension Deviation from drawings Black spots Ave . dia . D D 0.2 0.2<D 0.3 0.3<D 0.4 0.4<D Black lines Width W, Length L W 0.03 0.03<W 0.05 0.05<W 0. 3.0 See line criteria Bubbles in Average diameter D 0.2 < D < 0.5 mm polarizer for > 0.5 for Color Rainbow color or newton ring. ...

Page 15

... Low Temperature Storage Thermal Shock Test Humidity Test Vibration Test (Packing) Note 1 : Condensation of water is not permitted on the module. Note 2 : The module should be inspected after 1 hour storage in normal conditions (15-35°C , 45-65%RH). Definitions of life end point : Current drain should be smaller than the specific value. ...

Page 16

... Do not modify the display PCB in either shape or positioning of components. (5) Do not modify or move location of the zebra or heat seal connectors. (6) The device should only be soldered to during interfacing. Modification to other areas of the board should not be carried out. (7) In the event of LCD breakage and resultant leakage of fluid do not inhale, ingest or make contact with the skin ...

Page 17

... OUTLINE DIMENSION Date : 2006/9/12 AMPIRE CO., LTD. 17 ...