SPECIFICATIONS (TYPE: FMP)
*: Flow rate range may vary according to the viscosity, temperature, and pressure of the fluid.
FMP, M
Type
Nominal diameter, connection
Fluid
Flow rate range
(L/min) *
Permissible
ambient temper-
ature range
Maximum pressure
Accuracy
Reproducibility
Length of straight pipe
Pressure loss
(kPa) [see Fig. 1]
Main body material
Indicator (LCD digital display)
Output signal
Cable
Power supply
Structure
Backup (if with indicator)
Item
energized type
Environment
Battery type
Battery type
Externally
energized
Externally
For liquid
For liquid
For gas
For gas
Water
Water
Fluid
type
Air
Air
(1) Total flow: 8 digits
(2) Instantaneous flow rate (per hour): 5 digits
(3) Instantaneous flow rate (per minute): 5 digits
(4) Resettable total flow: 7 digits
4mm R
or Rc
4 to 20 mA DC analog (instantaneous flow rate) (see Fig. 3 Load Resistance Range); or
Pulse output (open collector). Rated values: 30 V DC, 20 mA.
Alarm output (H, L) ... Open collector.
Lithium battery unit. Life time: 4 years (at normal temperature) ... With weak battery alarm function.
1 /4
0.13 to 0.7
0.31 to 31
7.2 to 17
0.4 to 4
FMP2S
FMP3S
3 /8
female screw
Outdoor use (rainproof type), non-explosion-proof type. Direct sunshine not allowed.
male screw
5-core shielded cable (1 m) ... if with indicator, for externally energized type
3-core shielded cable (1 m) ... if without indicator
Upstream side: 7D or more, downstream side: 3D or more (see Fig. 2)
Water, pure water, or others (non-corrosive, non-inflammable)
Air, nitrogen, oxygen, argon, or others (non-inflammable gas)
Parameter settings and total value are held in EEPROM
8mm R
or Rc
1 /4
3% of full-scale measurement (see Fig. 1)
-10 to +80 C (no condensation allowed)
1.17 to 15
Pulse width: 30 ms (correct pulse) or 1 ms (non-correct pulse).
Duty ratio about 1:1 (non-correct pulse) ... If without indicator
18 to 90
12 to 45 V DC (type code 6th digit: 1)
12 to 24 V DC (type code 6th digit: 0)
FMP20
FMP30
1 /2
female screw
PPS resin (polyphenylene sulfide)
male screw
Rated values: 30 V DC, 20 mA.
-20 to +50 C
0.12 to 34.3
0.06 to 1.52
Description
0.98MPa
(1), (2), (3), or (4) can be selected by push button.
Flow rate unit [L, m
decimal point are indicated on LCD. (Orientation of the
indicator can be adjusted freely over 360 .)
* Alarm is indicated with LED (red).
None
0.5%
15mm R
or Rc
1 /2
55 to 283
2.8 to 45
FMP21
FMP31
3 /4
female screw
male screw
ON voltage: 1 V or less.
3
, g, kg, t, L (normal), m
... If with indicator
ON voltage: 1 V or less.
25mm R1
or Rc1 female screw
167 to 850
8.3 to 133
FMP22
FMP32
1 /4
3
(normal)] and
male screw

Related parts for EDS6-121A