EDS6-126 FUJI [Fuji Electric], EDS6-126 Datasheet - Page 3

no-image

EDS6-126

Manufacturer Part Number
EDS6-126
Description
OPTICAL DIFFERENTIAL PRESSURE TRANSMITTER REMOTE SEAL TYPE
Manufacturer
FUJI [Fuji Electric]
Datasheet
Capillary:
Finish:
Environmental protection:
External dimensions:
Mass:
Optical cable connection:
Indication unit: 5-digit LCD indication, % or real scale in-
Oxygen oil-proof processing:
Chlorine service: Fluorolube oil filled.
Table 1 Remote Control Function
Process connection:
Diaphragm extension:
Mounting method:
Maximum range
Measuring range
Damping
Real scale
indication
Battery voltage
Error indication
Measured value
Adjustment
Note: For operation of the “3” type transmitter (“3” at the 8th digit
Optional specifications
of product code), a hand-held communicator is required to
have a version 1.6 or higher, but a communicator before
version 1.6 can be operated with memory data updated.
(Refer to the instruction manual of transmitter.)
Item
(Items readable and setting from hand-held
communicator)
Reading Setting
dication (as specified by code symbol)
Operating temperature range: –20 to
+70 C
Fluorolube filled.
Wetted parts degreased
and cleaned.
Stainless steel pipe coated with PVC
Epoxy-polyurethane double coat,
Color: silver (blue for amplifier case cover)
Meets JIS C0920, immersion-proof
(equivalent to IEC IP67 or NEMA 6/6P)
See OUTLINE DIAGRAM.
13 to 30 kg
G1/2 or 1/2 -14NPT (whichever selected
by code symbol)
JIS specifications;
ANSI/JPI specifications;
0, 50, 100, 150 or 200 mm (as specified)
U-bolt mounting to a 50A (2B) pipe. De-
tection unit is mounted with flange or
between flanges (wafer type).
10K, 20K, 30K-40A, 50A
10K, 30K-80A, 100A
150LB, 300LB, 1-1/2B, 2B, 3B, 4B
Maximum measuring range
of equipment
Actual measuring range
Variable within 0.2 to 32 sec.
Indication in industrial value
Battery voltage of equipment
Errors of detection unit and
amplifier
Measured data
Zero and span adjustment
Description
Varies with
material.
Refer to
CODE
SYMBOLS.
[kPa abs]
Fig. 1 Relation between process temperature and
Fig. 2 Relation between process temperature and
[kPa abs]
101
53.3
13.3
2.7
101
0.27
0.13
Note: For use at a vacuum level, the transmitter body should be
operating pressure
operating pressure
-40 -15 0
Fill-fluid: Silicon oil (Code: Y,G)
mounted below the flange section mounting position.
-15
Fill-fluid: Silicon oil (Code: S)
Fill-fluid: Silicon oil (Code: K)
Operating area
With
small bore
60 85
Process temperature
Operating area
Process temperature
120
Non-operating area
100
Fill-fuid: Silicon oil (Code: T)
200 230250
200
Non-
operating
area
[ C]
300
[ C]
3

Related parts for EDS6-126