EDS6-50I FUJI [Fuji Electric], EDS6-50I Datasheet

no-image

EDS6-50I

Manufacturer Part Number
EDS6-50I
Description
DIFFERENTIAL PRESSURE DEVICE ORIFICE PLATE WITH CARRIER RINGS
Manufacturer
FUJI [Fuji Electric]
Datasheet
steam, and gas in low or medium pressure, lines. Tapping
of differential pressure is done by comer tap method with
differential pressure tapping rings having CARRIER RINGS.
One set is composed of differential pressure tapping rings,
an orifice plate, and a gasket. CARRIER RINGS are installed
to average the differential pressure inside the rings.
SPECIFICATIONS
Type:
Calculation standard:
Nominal pipe size: 25A to 300A
Materials of main elements:
Gasket:
Mount direction: Horizontal
< Table 1 >
Type
No. 6500AC
(Non-asbestos)
No. 7020
(Teflon)
No. GF300
(Graphite compound)
No. 6590T
(Pure graphite)
FFI SYSTEM
DATA SHEET
This orifice plate is widely used for measuring liquid,
Corner taps
According to concentric edge
JIS Z 8762-1995 (ISO 5167-1:1991)
Ring;
Orifice plate; SUS304, SUS316 or PVC
Differential pressure tapping pipe;
Differential pressure outlet flange;
Valqua (Refer to table 1)
Vertical (Down to up)
Vertical (Up to down)
Please specify in the specification
sheet.
These orifice plates with CARRIER
RINGS can be supplied for nominal pipe
sizes up to 1000A. Type FVB orifice plate
is recommended for sizes 400A and
above.
Application
General use
For no oil treatment 1.5MPa, 200°C
For high temp. high
press. *
For high temp. high
press. *
DIFFERENTIAL PRESSURE DEVICE
ORIFICE PLATE
SS400, SF440A, SUS304,
SUS316 or PVC
ST P G 3 7 0 , S U S 3 0 4 o r
SUS316
SS400, SF440A, SUS304 or
SUS316
Rating (about)
3MPa, 100°C
3MPa, 230°C
20MPa, 400°C
*Non-standard
WITH CARRIER RINGS
Connection method:
Operating conditions:
Differential pressure outlet size:
Connection flange;
JIS 5, 10, 20, 30K
ANSI 150, 300, 400Lb
Max. pressure; 3Mpa {30.59kgf/cm
less
Temperature range; −10 to 300°C
R1/2
JIS 15A welded type
Flange standard; JIS 5K 15A RF
Use single-part orifice plate (type
FVE) for flange standard of JIS 40K,
ANSI 600Lb or higher.
(depends on the kind of fluid)
JIS 10K 15A RF
JIS 20K 15A RF
JIS 30K 15A RF
Date
EDS6-50i
FVA
Apr. 1, 2011
2
} or

Related parts for EDS6-50I

EDS6-50I Summary of contents

Page 1

... FVE) for flange standard of JIS 40K, ANSI 600Lb or higher. Max. pressure; 3Mpa {30.59kgf/ less Temperature range; −10 to 300°C (depends on the kind of fluid) R1/2 JIS 15A welded type Flange standard; JIS 5K 15A RF JIS 10K 15A RF JIS 20K 15A RF JIS 30K 15A RF EDS6-50i Date Apr. 1, 2011 ...

Page 2

FVA CODE SYMBOLS Notes: (1) Combination of orifice plates and rings Orifice plate Ring (2) With ring material SS400: Pressure rating for (pipe) flange ≤ 10K Working temperature ≤ 300°C (3) With ...

Page 3

OUTLINE DIAGRAM (Unit: mm) φA Nominal pipe e diameter (A) 5K 10K 20K 30K 0.2~0 0.3~0 0.3~0 101 101 111 0.5~0.8 65 115 ...

Page 4

FVA ORDERING INFORMATION 1. Code symbols 2. Kind, composition and density of fluid 3. Temperature, pressure, relative humidity and viscosity (heat insulation index for gas) of fluid 4. Flow rate (maximum, normal, minimum) 5. Instrument scale 6. Inside diameter (measured ...