EDS6-85E FUJI [Fuji Electric], EDS6-85E Datasheet - Page 8

no-image

EDS6-85E

Manufacturer Part Number
EDS6-85E
Description
Manufacturer
FUJI [Fuji Electric]
Datasheet
Head office
11-2 Osaki 1-chome, Shinagawa-ku, Tokyo, 141-0032 Japan
Phone: 81-3-5435-7111
http://www.fujielectric.co.jp/eng/sg/KEISOKU/welcome.htm
Information in this catalog is subject to change without notice.
FHC, FKC ... 2
Note *: Cable gland is supplied in case of flameproof packing type.
The product conforms to the requirements of the Elec-
tromagnetic compatibility Directive 89/336/EEC as de-
tailed within the technical construction file number
TN510412.
4th of code symbols
"S" type
4th of Code symbols
"T, V, W, X" type
Mtg. pipe
JIS 50A (2B)
F
Details of "A"
Details of "B"
H
K
4 holes
9 dia.
4
ø11 cable is suitable.
C
12
16
16
W
S
V
X
T
+0.2
+0.1
4
1/4–18NPT
B
U
L
58
38
2
U-bolt
Details of "C"
M8
See table 1
40
58
15
E
4th of Code
symbols
Vent/drain plug
CONNECTION DIAGRAM
W
S
T
V
X
"A"
Press. conn.
Oval flange
screw
See table 1
or
+
G1/2
1/2-14NPT
Pg13.5
M20x1.5
Pg13.5
210
"B"
Conduit conn.
E
CK + CK –
Details of "D"
+ –
17
16
16
F
8
8
4th of Code symbols
"S, V, W, X" type is not attached
G1/2
4.5
4.5
G
8
5
5
Table 1
Zero/span adj. screw
Oval flange
screw
7/16-20UNF
screw depth 13
7/16-20UNF
screw depth 13
M10
screw depth 13
M10
screw depth 13
7/16-20UNF
screw depth 13
(27)
With field ind.
13
"
Conduit conn.
C
"
Sales Div.
International Sales Dept.
No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan
Phone: 81-42-585-6201, 6202
Fax: 81-42-585-6187
The applicable standards used to demonstrate com-
pliance are :-
EMI (Emission) EN 50081-1 :-1992
EMS (Immunity) EN 50082-1 :-1992
No.
"LVD - The transmitter is not covered by the requirements
of the LVD standard."
Earth
terminal
No. 8-32UNC
1
2
3
Applicable Electromagnetic
Radiation Disturbance
Down
Up
Electrostatic
discharge
Radio-frequency
electromagnetic
field.
Fast transients
common mode
M4
M4
M4
M4
Test item
Earth terminal
(both side)
See table 1
Test item
4–M8x12
L.P.
Test specification
8kV (Air)
27-500MHz
3V/m
(Unmodulated)
0.5kV, 5/50(Tr/Th)ns
5kHz Rep.
Field ind. (option)
*Cable gland
Frequency ranme
91
30-1000MHz
104
54
186
70
IEC 801-2 : 1984
IEC 801-3 : 1984
IEC 801-4 : 1988
Basic standard
43
Fastener
(flameproof model only)
"
Conduit conn.
D
H.P.
"
Basic standard
EN55022
Class B
Performance
criteria
Printed in Japan
B
A
B

Related parts for EDS6-85E