SM363FX COOPER [Cooper Bussmann, Inc.], SM363FX Datasheet - Page 4

no-image

SM363FX

Manufacturer Part Number
SM363FX
Description
Safety Module fused disconnect switch
Manufacturer
COOPER [Cooper Bussmann, Inc.]
Datasheet
310
Type EP
• Complies with the new 2005 NEC
• Ensures system uptime with the goal of safety of human life
• Provides a fast and easy solution to meeting new coordination
• Offers significant savings compared to other fused panels and
• Hospitals
• Schools
• Commercial and industrial facilities
Catalog Numbers
EP2M23012GCC
EP2M23024GCC
EP2M23036GCC
EP2M23042GCC
EP4M23012GCC
EP4M23024GCC
EP4M23036GCC
EP4M23042GCC
* Meets UL 67 (Panelboards) and UL 50 (Cabinets and Boxes).
** When protected by upstream LPN-RK 100A max. LPJ 200A max. or JJN 200A max., otherwise 10kA.
*** When protected by upstream LPN-RK 200A max. LPJ 200A max. or JJN 200A max., otherwise 14kA.
Cooper Bussmann
Specifications
Description: A fused lighting and appliance panelboard for
branch circuit applications. Specifically designed to meet the
2005 NEC
Emergency, Legally Required Standby and Essential Electrical
Systems per 700.27, 701.18, and 517.26 when properly coordi-
nated with the upstream overcurrent protective device feeder.
Circuits: 12, 24, 36, 42
Enclosure: NEMA 1
Ratings:
Agency Information: UL67, UL 50.
Features and Benefits
Typical Applications
Catalog Numbers
Branch Circuit Amps: — 0-30A
SCCR: — 100kA
Volts: — 120/208 or 277/480Vac
Requirements for Emergency, Legally Required Standby and
Essential Electrical Systems per 700.27, 701.18, and 517.26
when properly coordinated with the upstream overcurrent
protective device feeder. Per the 2005 NEC
(Selective) is the localization of an overcurrent condition to
restrict outages to the circuit or equipment affected,
accomplished by the choice of overcurrent protective devices
and their ratings or settings.
during emergencies or for essential health care functions.
Code requirements. Simply utilize published fuse selective
coordination ratios to select the correct upstream fuse ratings.
selectively coordinated circuit breaker systems.
Disconnects
Coordination Module™ fused lighting and
appliance panelboard
®
Code requirements for selective coordination for
For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp
120/208
120/208
120/208
120/208
277/480
277/480
277/480
277/480
Voltage
Rating
®
Coordination Module™
Coordination Module*
®
Selective Coordination
100kA***
100kA***
100kA***
100kA***
100kA**
100kA**
100kA**
100kA**
SCCR
®
: Coordination
Height Width Depth
36
38
48
48
36
36
48
48
Dimensions (in)
28
28
28
28
28
28
28
28
5
5
5
5
5
5
5
5
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
Type
MLO
MLO
MLO
MLO
MLO
MLO
MLO
MLO
Main Device
Amp Rating
200
200
200
200
200
200
200
200
Rating
Amp
30
30
30
30
30
30
30
30
Branch Circuit
Number of
Circuits
12
24
36
42
12
24
36
42

Related parts for SM363FX