SIPMOS ® Small-Signal-Transistor Features • P-Channel • Enhancement mode • Avalanche rated • dv /dt rated • Pb-free lead finishing; RoHS compliant Type Package BSP 170 P PG-SOT-223 Maximum ratings =25 °C, unless otherwise specified j Parameter Continuous ...
Page 2
Parameter Thermal characteristics Thermal resistance, junction -soldering point SMD version, device on PCB: Electrical characteristics Static characteristics Drain-source breakdown voltage Gate threshold voltage Zero gate voltage drain current Gate-source leakage current Drain-source on-state resistance Transconductance 1) Device on ...
Page 3
Parameter Dynamic characteristics Input capacitance Output capacitance Reverse transfer capacitance Turn-on delay time Rise time Turn-off delay time Fall time Gate Charge Characteristics Gate to source charge Gate to drain charge Gate charge total Gate plateau voltage Reverse Diode Diode ...
Page 4
Power dissipation P =f(T ) tot A 1.8 1.5 1.2 0.9 0.6 0 Safe operating area =25 ° parameter ...
Page 5
Typ. output characteristics I =f =25 ° parameter - -6V - Typ. transfer characteristics I ...
Page 6
Drain-source on-state resistance R =f =-1 DS(on 600 550 500 450 400 98 % 350 300 250 200 150 100 50 0 -60 - Typ. capacitances C =f(V ); ...
Page 7
Avalanche characteristics =25 Ω parameter: T j(start Drain-source breakdown voltage V =f =-250 µA BR(DSS ...
Page 8
Package Outline SOT-223: Outline Footprint Operating and storage temperature Dimensions in mm Rev 2.52 Packaging Tape page 8 BSP 170 P 2009-02-16 ...
Page 9
... Infineon Technologies Office. Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infineon Technologies failure of such components can reasonably be expected to cause the failure of that life-support device or system affect the safety or effectiveness of that device or system. Life support devices or systems are intended to be implanted in the human body support and/or maintain and sustain and/or protect human life ...