PCA2129T/Q900/2,51 NXP Semiconductors, PCA2129T/Q900/2,51 Datasheet - Page 39

no-image

PCA2129T/Q900/2,51

Manufacturer Part Number
PCA2129T/Q900/2,51
Description
Real Time Clock
Manufacturer
NXP Semiconductors
Series
PCA2129r
Datasheet

Specifications of PCA2129T/Q900/2,51

Rohs
yes
Function
Clock, Calendar, Alarm, Watchdog, Timestamp
Rtc Bus Interface
I2C, SPI
Date Format
Binary
Time Format
Binary
Supply Voltage - Max
4.2 V
Supply Voltage - Min
1.8 V
Maximum Operating Temperature
+ 80 C
Minimum Operating Temperature
- 30 C
Mounting Style
SMD/SMT
Package / Case
SOP-16
Battery Backup Switching
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PCA2129T/Q900/2,51
Manufacturer:
NXP/恩智浦
Quantity:
20 000
NXP Semiconductors
PCA2129T
Product data sheet
8.12.1 Minute and second interrupts
The control bit TI_TP (register Watchdg_tim_ctl) is used to configure whether the
interrupts generated from the second/minute timer (flag MSF in register Control_2) are
pulsed signals or a permanently active signal. All the other interrupt sources generate a
permanently active interrupt signal which follows the status of the corresponding flags.
When the interrupt sources are all disabled, INT remains high-impedance.
Minute and second interrupts are generated by predefined timers. The timers can be
enabled independently from one another by the bits MI and SI in register Control_1.
However, a minute interrupt enabled on top of a second interrupt will not be
distinguishable since it will occur at the same time.
The minute/second flag MSF (register Control_2) is set logic 1 when either the seconds or
the minutes counter increments according to the enabled interrupt (see
MSF flag can be cleared by command.
Table 46.
When MSF is set logic 1:
MI SI Result on INT
0
1
0
1
Fig 20. INT example for SI and MI when TI_TP is logic 1
The flags MSF, AF, TSFx, and BF can be cleared by command.
The flag WDTF is read only. How it can be cleared is explained in
The flag BLF is read only. It is cleared automatically from the battery low detection
circuit when the battery is replaced.
If TI_TP is logic 1, the interrupt is generated as a pulsed signal.
If TI_TP is logic 0, the interrupt is permanently active signal that remains until MSF is
cleared.
0
0
1
1
MSF when only MI enabled
INT when only MI enabled
MSF when SI enabled
no interrupt generated
an interrupt once per minute
an interrupt once per second
an interrupt once per second
INT when SI enabled
In this example, bit TI_TP is logic 1 and the MSF flag is not cleared after an interrupt.
Effect of bits MI and SI on pin INT and bit MSF
seconds counter
minutes counter
All information provided in this document is subject to legal disclaimers.
Rev. 3 — 24 January 2013
Accurate RTC with integrated quartz crystal for automotive
58
59
Result on MSF
MSF never set
MSF set when minutes counter increments
MSF set when seconds counter increments
MSF set when seconds counter increments
59
11
00
12
PCA2129T
00
Section
© NXP B.V. 2013. All rights reserved.
Table
01
46). The
8.10.5.
001aaf905
39 of 72

Related parts for PCA2129T/Q900/2,51