7.14.1 Node Configuration (bit 19.15)
7.14.2 Hardware/Software Priority Status (bit 19.14)
7.14.3 Remote Fault (bit 19.13)
7.14.4 ICS Reserved (bits 19.12:10)
7.14.5 Auto-MDI/MDIX (bits 19. 9:8) (New)
ICS1893BF, Rev. F, 5/13/10
The Node Configuration bit indicates the NOD/MODE.
•
•
The Hardware/Software Priority Status bit indicates the SW mode.
•
•
The ISO/IEC specification defines bit 5.13 as the Remote Fault bit, and bit 19.13 is functionally identical to
bit 5.13. The Remote Fault bit is set based on the Link Control Word received from the remote link partner.
When this bit is a logic:
•
•
See
The ICS1893BF includes the Auto-MDI/MDIX crossover feature. The Auto-MDI/MDIX feature automatically
selects the correct MDI or MDIX configuration to match the cable plant by automatically swapping transmit
and receive signal pairs at the PHY. Auto-MDI/MDIX is defaulted on but may be disabled for test purposes
using either the AMDIX_EN (pin 10) or by writing (bits 19. 9:8). See Table 7-22 for AMDIX_EN (19,9) and
MDI_MODE (19,8) operation.
When AMDIX_EN (bit 19,9) is set to 0, the twisted pair transmit/receive is forced by the MDI_MODE bit
(19,8).
Note:
Table 7-22. AMDIX_EN (Pin 10) and Control Bits 19. 9:8
In Node mode:
The ICS1893BF will only operate in the Node Configuration.
The (MDIO) register bits control the ICS1893BF configuration.
The ICS1893BF will only operate in the Software Configuration.
Zero, it indicates the remote link partner does not detect a Link Fault.
One, it indicates to an STA that the remote link partner detects a Link Fault.
– The SQE Test default setting is enabled.
– The Carrier Sense signal (CRS) is asserted in response to either transmit or receive activity.
Section 7.11.2, “ICS Reserved (bits
ICS1893BF Data Sheet - Release
AMDIX_EN
Holding (Pin 10) AMDIX_EN low will also disable the Auto_MDIX function and force pins TP_AP
and TP_AN to be the transmit pair and TP_BP and TP_BN to be the receive pair. AMDIX_EN has
a built in 50K Ohm internal pull-up.
(Pin 10)
x
x
0
AMDIX_EN
[Reg 19:9]
0
0
1
Copyright © 2009, IDT, Inc.
16.14:11)”, the text for which also applies here.
All rights reserved.
88
MDI_MODE
[Reg 19:8]
0
1
x
Chapter 7 Management Register Set
Configuration
Tx/Rx MDI
straight
straight
cross
May, 2010
Related parts for 1893BKLFT
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
Ethernet ICs 3.3V 10/100 BASE TX INTEGRATED PHYCEIVER
Manufacturer:
IDT
Part Number:
Description:
PHYCEIVER LOW PWR 3.3V 56-MLF2
Manufacturer:
IDT, Integrated Device Technology Inc
Datasheet:
Part Number:
Description:
IDT TS3000AND TSE2002 SENSORS SAMPLE PACK OFFER
Manufacturer:
Integrated Device Technology (Idt)
Part Number:
Description:
THERMOCOUPLE DIGITAL PANEL METER
Manufacturer:
NEWPORT ELECTRONICS
Part Number:
Description:
High-performance CMOS bus interface latches
Manufacturer:
Integrated Device Technology, Inc.
Part Number:
Description:
Accessories Connectors and Cables
Manufacturer:
ADVANTECH [Advantech Co., Ltd.]
Datasheet:
Part Number:
Description:
Accessories 5.25 Industrial Disk Tray
Manufacturer:
ADVANTECH [Advantech Co., Ltd.]
Datasheet:
Part Number:
Description:
IDT PART
Manufacturer:
IDT, Integrated Device Technology Inc
Datasheet: