MAXREADERKIT-EUR Cypress Semiconductor, MAXREADERKIT-EUR Datasheet - Page 26

no-image

MAXREADERKIT-EUR

Manufacturer Part Number
MAXREADERKIT-EUR
Description
Memory IC Development Tools MaxReader Dev Kit (Tuned to Europe)
Manufacturer
Cypress Semiconductor
Datasheet

Specifications of MAXREADERKIT-EUR

Rohs
yes
Product
Development Kit
Tool Is For Evaluation Of
WM72016
Memory Size
16 Kbit
Memory Type
F-RAM with Gen-2 RFID
Operating Supply Voltage
5 V
Interface Type
DSPI Serial
Factory Pack Quantity
1
4.3 Read Instructions
Gen2 read instructions are performed through the CLI by using the target memory bank (or register) in the name of the
CLI command. It is inferred that commands that do not include the Gen2 memory bank name are accessing the USER
memory bank. In addition, read commands may specify single or multiple words, MaxArias registers, or use extended
EBV-formatted addressing.
Syntax
Function
Parameters
Cmd Reply
Description
4.3.1 G2READ: Gen2 Read
CLI Command
G2READ
G2READX
G2READRSVD
G2READEPC
G2READTID
G2READUSER
G2READCNTL
G2READSTRDADDR Gen2 MaxArias Working Stored Address read
G2READ {addr} {len}
Gen2 USER memory bank read command
data
Performs a standard Gen2 read command on the USER memory bank using a single 8-bit address
parameter (note: Gen2 read instructions of the other memory banks are performed with other CLI
commands described later in this section). The G2READ command has 2 parameters: address (addr)
and length (len). The address parameter defines the read instruction starting address and may not be
larger than x7F; the length parameter defines the number of words, with the first word being
addressed in the command’s address parameter – the length parameter can take on any value between
x0 and xFF.
NOTE:
Parameter
addr
len
1. Once the address and length parameters have been entered in an instruction, subsequent read
2. As defined in the Gen2 standard, if the length parameter is set to null (0x00), the tag shall
0
, data
instructions may be repeated without re-entering the parameters – entering the command on
its own will produce the same result. In addition, a subsequent read instruction may only
define the address – the previously defined length parameter will continue to be used.
respond with read data starting at the address defined in the read instruction, and continue to
the end of the memory bank.
1
, …, data
Value (hex)
00-7F
00-FF
Description
Gen2 read – single-byte addressing
Gen2 read – EBV-formatted addressing
Gen2 RESERVED memory bank read
Gen2 EPC memory bank read
Gen2 TID memory bank read
Gen2 USER memory bank read
Gen2 MaxArias Control/Status read
len-2
, data
len-1
Definition
, Handle, CRC16
MaxReader CLI User Guide v1.05
~
2 6
~

Related parts for MAXREADERKIT-EUR