ISL8225MEVAL4Z Intersil, ISL8225MEVAL4Z Datasheet
ISL8225MEVAL4Z
Specifications of ISL8225MEVAL4Z
Related parts for ISL8225MEVAL4Z
ISL8225MEVAL4Z Summary of contents
Page 1
... Easy access to all pins, with few external components, reduces PCB design to a component layer and a simple ground layer. This ISL8225MEVAL4Z evaluation board is designed for dual 15A output applications. Optionally, this board can easily be converted for 30A single output use. Multiple ...
Page 2
... Add C2 for a 470pF capacitor. 3. Connect a power supply capable of sourcing at least 5A to the inputs BA7 (VIN1), BA8 (GND), BA3 (VIN2) and BA4 (GND) of the ISL8225MEVAL4Z evaluation board, with a voltage between 4.5V to 20V. VIN1 and VIN2 need to be shorted together. 4. Connect an electronic load or the device to be powered to the outputs BA5 (VOUT1) and BA6 (GND) of the board ...
Page 3
However, if the output voltage is increased or the board is operated at elevated temperatures, then the available current is derated. Refer to the derated current curves in the determine the output current available. For layout of designs using the ...
Page 4
MODULE (I = INPUT OUTPUT; I/O = INPUT AND OUTPUT, BI-DIRECTION) EN1/FF1 EN2/FF2 VSEN2- MODE MODE (I) (I) (I) ( Active Active Active ...
Page 5
... PHASE2 PHASE1 9 PHASE2 PHASE1 2 1 JP1 ENC EN/FF2 OUT R18 VIN2 VIN1 DNP R19 DNP GROUND ARE TIED TOGETHER AT PIN 6 OF U1. E FIGURE 2. ISL8225MEVAL4Z BOARD SCHEMATIC VOUT1 C12 1000PF R22 E OPEN R21 VCC IN DNP COMP1 20 OUT ISHARE ...
Page 6
Layout FIGURE 3. TOP SILK SCREEN FIGURE 5. LAYER 2 FIGURE 4. TOP LAYER COMPONENT SIDE FIGURE 6. LAYER 3 ...
Page 7
Layout (Continued) FIGURE 7. BOTTOM LAYER SOLDER SIDE FIGURE 8. BOTTOM SILK SCREEN ...
Page 8
Bill of Materials PART NUMBER REF DES 10TPB330M C04, C08 131-4353-00 J1, J4 2N7002-7-F Q1 31-5329-52RFX J2, J5 5002 P1-P8 575-4 BA1-BA8 EEVHA1E331UP CIN1, CIN4 GRM21BR71C475KA73L C1 GRM32ER71A476KE15L C01, C03, C05, C07 H1045-OPEN C2, C3, C6, C7 H1045-00102-16V10 C15, C16 ...
Page 9
... ISL8225MEVAL4Z Efficiency Curves 100 LOAD CURRENT (A) FIGURE 9. EFFICIENCY vs LOAD CURRENT (5V Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time without notice. Accordingly, the reader is cautioned to verify that the Application Note or Technical Brief is current before proceeding. ...