Specifications of MAX17058EVKIT#

Part # Aliases
90-BCA1K#D00
The read data protocol is used to read to register from the
ICs starting at the memory address specified by MAddr.
Both register bytes must be read in the same transaction
for the register data to be valid. Data0 represents the
data byte in memory location MAddr, Data1 represents
the data from MAddr + 1, and DataN represents the last
byte read by the master:
+Denotes a lead(Pb)-free/RoHS-compliant package.
*EP = Exposed pad.
T = Tape and reel.
For the latest package outline information and land patterns (footprints), go to www.maxim-ic.com/packages. Note that a “+”, “#”, or
“-” in the package code indicates RoHS status only. Package drawings may show a different suffix character, but the drawing pertains
to the package regardless of RoHS status.
MAX17058G+
MAX17058G+T10
MAX17058X+
MAX17058X+T10
MAX17059G+
MAX17059G+T10
MAX17059X+
MAX17059X+T10
PACKAGE TYPE
S. SAddr W. A. MAddr. A. Sr. SAddr R. A.
8 TDFN-EP
8 WLP
PART
Data0. A. Data1. A... DataN. N. P
Read Data Protocol
PACKAGE CODE
-40NC to +85NC
-40NC to +85NC
-40NC to +85NC
-40NC to +85NC
-40NC to +85NC
-40NC to +85NC
-40NC to +85NC
-40NC to +85NC
TEMP RANGE
W80B1+1
T822+3
1-Cell /2-Cell Li+ ModelGauge ICs
PIN-PACKAGE
8 TDFN-EP*
8 TDFN-EP*
8 WLP
8 WLP
8 TDFN-EP*
8 TDFN-EP*
8 WLP
8 WLP
Data is returned beginning with the MSB of the data
in MAddr. Because the address is automatically incre-
mented after the LSB of each byte is returned, the MSB
of the data at address MAddr + 1 is available to the
host immediately after the acknowledgment of the data
at address MAddr. If the bus master continues to read
beyond address FFh, the ICs output data values of
FFh. Addresses labeled Reserved in the memory map
return undefined data. The bus master terminates the
read transaction at any byte boundary by issuing a no
acknowledge followed by a STOP or Repeated START.
MAX17058 /MAX17059
OUTLINE NO.
21-0555
21-0168
Ordering Information
Package Information
Application Note 1891
1-Cell ModelGauge IC
1-Cell ModelGauge IC
1-Cell ModelGauge IC
1-Cell ModelGauge IC
2-Cell ModelGauge IC
2-Cell ModelGauge IC
2-Cell ModelGauge IC
2-Cell ModelGauge IC
LAND PATTERN NO.
DESCRIPTION
90-0065
Refer to
15

Related parts for MAX17058EVKIT#