Description
IC FLASH 1MBIT 90NS 32PLCC
Manufacturer
Winbond Electronics
Datasheet

Specifications of W29EE011P90Z

Format - Memory
FLASH
Memory Type
FLASH
Memory Size
1M (128K x 8)
Speed
90ns
Interface
Parallel
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
0°C ~ 70°C
Package / Case
32-PLCC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
W29EE011P90Z
Manufacturer:
WINBOND
Quantity:
1 000
Part Number:
W29EE011P90Z
Manufacturer:
OKI
Quantity:
720
Part Number:
W29EE011P90Z
Manufacturer:
Winbond Electronics
Quantity:
10 000
Part Number:
W29EE011P90Z
Manufacturer:
WINBOND
Quantity:
7
6. FUNCTIONAL DESCRIPTION
6.1
The read operation of the W29EE011 is controlled by #CE and #OE, both of which have to be low for
the host to obtain data from the outputs. #CE is used for device selection. When #CE is high, the chip is
de-selected and only standby power will be consumed. #OE is the output control and is used to gate
data from the output pins. The data bus is in high impedance state when either #CE or #OE is high.
Refer to the timing waveforms for further details.
6.2
The W29EE011 is programmed on a page basis. Every page contains 128 bytes of data. If a byte of
data within a page is to be changed, data for the entire page must be loaded into the device. Any byte
that is not loaded will be erased to "FFh" during programming of the page.
The write operation is initiated by forcing #CE and #WE low and #OE high. The write procedure
consists of two steps. Step 1 is the byte-load cycle, in which the host writes to the page buffer of the
device. Step 2 is an internal programming cycle, during which the data in the page buffers are
simultaneously written into the memory array for non-volatile storage.
During the byte-load cycle, the addresses are latched by the falling edge of either #CE or #WE,
whichever occurs last. The data are latched by the rising edge of either #CE or #WE, whichever occurs
first. If the host loads a second byte into the page buffer within a byte-load cycle time (T
µS, after the initial byte-load cycle, the W29EE011 will stay in the page load cycle. Additional bytes can
then be loaded consecutively. The page load cycle will be terminated and the internal programming
cycle will start if no additional byte is loaded into the page buffer within 300 µS (T
byte-load cycle, i.e., there is no subsequent #WE high-to-low transition after the last rising edge of
#WE. A
same page address. A
order; sequential loading is not required.
In the internal programming cycle, all data in the page buffers, i.e., 128 bytes of data, are written
simultaneously into the memory array. Before the completion of the internal programming cycle, the
host is free to perform other tasks such as fetching data from other locations in the system to prepare to
write the next page.
6.3
The device provides a JEDEC-approved optional software-protected data write. Once this scheme is
enabled, any write operation requires a series of three-byte program commands (with specific data to a
specific address) to be performed before the data load operation. The three-byte load command
sequence begins the page load cycle, without which the write operation will not be activated. This write
scheme provides optimal protection against inadvertent write cycles, such as cycles triggered by noise
during system power-up and power-down.
The W29EE011 is shipped with the software data protection enabled. To enable the software data
protection scheme, perform the three-byte command cycle at the beginning of a page load cycle. The
device will then enter the software data protection mode, and any subsequent write operation must be
preceded by the three-byte program command cycle. Once enabled, the software data protection will
remain enabled unless the disable commands are issued. A power transition will not reset the software
data protection feature. To reset the device to unprotected mode, a six-byte command sequence is
required. See Table 3 for specific codes and Figure 10 for the timing diagram.
Read Mode
Page Write Mode
Software-protected Data Write
7
to A
16
specify the page address. All bytes that are loaded into the page buffer must have the
0
to A
6
specify the byte address within the page. The bytes may be loaded in any
- 6 -
W29EE011
BLCO
BLC
) from the last
) of 200