TOP246YN Power Integrations, TOP246YN Datasheet - Page 32

IC OFFLINE SWIT UVLO HV TO220

TOP246YN

Manufacturer Part Number
TOP246YN
Description
IC OFFLINE SWIT UVLO HV TO220
Manufacturer
Power Integrations
Series
TOPSwitch®-GXr
Type
Off Line Switcherr
Datasheet

Specifications of TOP246YN

Output Isolation
Isolated
Frequency Range
66 ~ 132kHz
Voltage - Output
700V
Power (watts)
125W
Operating Temperature
-40°C ~ 150°C
Package / Case
TO-220-7 (Formed Leads), 5 Leads
Output Voltage
12 V
Input / Supply Voltage (max)
265 VAC
Input / Supply Voltage (min)
85 VAC
Duty Cycle (max)
83 %
Switching Frequency
132 KHz
Supply Current
2.2 mA
Operating Temperature Range
- 40 C to + 150 C
Mounting Style
Through Hole
No. Of Outputs
1
Output Current
4.32A
No. Of Pins
6
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
596-1077-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TOP246YN
Manufacturer:
POWER
Quantity:
4 000
Part Number:
TOP246YN
Manufacturer:
POWER
Quantity:
10 000
Part Number:
TOP246YN
Manufacturer:
WSI
Quantity:
108
Part Number:
TOP246YN
Manufacturer:
POWER
Quantity:
20 000
Part Number:
TOP246YN
Manufacturer:
POWER
Quantity:
14 377
Part Number:
TOP246YN
0
Company:
Part Number:
TOP246YN
Quantity:
9 000
Figure 49. Layout Considerations for TOPSwitch-GX using R Package.
Quick Design Checklist
As with any power supply design, all TOPSwitch-GX designs
should be verified on the bench to make sure that components
specifications are not exceeded under worst case conditions. The
following minimum set of tests is strongly recommended:
1. Maximum drain voltage – Verify that peak V
2. Maximum drain current – At maximum ambient temperature,
32
exceed 675 V at highest input voltage and maximum
overload output power. Maximum overload output power
occurs when the output is overloaded to a level just before the
power supply goes into auto-restart (loss of regulation).
maximum input voltage and maximum output load, verify
drain current waveforms at start-up for any signs of
transformer saturation and excessive leading edge current
spikes. TOPSwitch-GX has a leading edge blanking time of
220 ns to prevent premature termination of the ON-cycle.
Verify that the leading edge current spike is below the
allowed current limit envelope (see Figure 52) for the
drain current waveform at the end of the 220 ns blanking
period.
TOP VIEW
TOP242-250
O
11/05
Solder Side
Component Side
HV
+
-
R1a - 1c
TOPSwitch-GX
X
D
L
C
Input Filter
DS
S
Capacitor
does not
3. Thermal check – At maximum output power, minimum
Design Tools
For a discussion on utilizing TOP248, TOP249 and TOP250
in forward converter configurations, please refer to the
TOPSwitch-GX Forward Design Methodology Application
Note.
Up-to-date information on design tools can be found at the
Power Integrations website: www.powerint.com
BIAS
PRI
PRI
input voltage and maximum ambient temperature, verify
that temperature specifications are not exceeded for
TOPSwitch-GX, transformer, output diodes and output
capacitors. Enough thermal margin should be allowed for
the part-to-part variation of the R
as specified in the data sheet. The margin required can
either be calculated from the tolerances or it can be
accounted for by connecting an external resistance in
series with the DRAIN pin and attached to the same
heatsink, having a resistance value that is equal to the
difference between the measured R
under test and the worst case maximum specification.
Safety Spacing
Capacitor
coupler
Opto-
Y1-
m
T
a
n
s
o
e
r
f
r
r
SEC
Maximize hatched copper
areas (
heat sinking
DS(ON)
Output Filter Capacitors
) for optimum
DS(ON)
of TOPSwitch-GX,
of the device
-
PI-2734-043001
Out
DC
+

Related parts for TOP246YN