LTC2941IDCB-1#TRPBF Linear Technology, LTC2941IDCB-1#TRPBF Datasheet - Page 3

no-image

LTC2941IDCB-1#TRPBF

Manufacturer Part Number
LTC2941IDCB-1#TRPBF
Description
IC FUEL/GAS GAUGE LI-ION 1A 6DFN
Manufacturer
Linear Technology
Datasheet

Specifications of LTC2941IDCB-1#TRPBF

Function
Fuel, Gas Gauge/Monitor
Battery Type
Lithium-Ion (Li-Ion)
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
6-WFDFN Exposed Pad
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
LTC2941IDCB-1#TRPBFLTC2941IDCB-1
Manufacturer:
LT
Quantity:
10 000
Company:
Part Number:
LTC2941IDCB-1#TRPBFLTC2941IDCB-1#PBF/CD
Manufacturer:
LT
Quantity:
183
Company:
Part Number:
LTC2941IDCB-1#TRPBFLTC2941IDCB-1#TRMPBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Company:
Part Number:
LTC2941IDCB-1#TRPBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
elecTrical characTerisTics
temperature range, otherwise specifications are at T
SYMBOL
Digital Inputs and Digital Outputs
V
V
I
C
t
I
f
t
t
t
t
t
t
t
t
Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime.
Note 2: All currents into pins are positive, all voltages are referenced to
GND unless otherwise specified
Note 3: I
Note 4: The equivalent charge of an LSB in the accumulated charge
registers (C,D) depends on the setting of the internal pre-scaling factor M.
It is calculated by:
Timing Diagram
IN
PCC
2
SCL(MAX)
BUF(MIN)
SU,STA(MIN)
HD,STA(MIN)
SU,STO(MIN)
SU,DAT(MIN)
HD,DATI(MIN)
HD,DATO
of
ITH
OL
IN
C Timing Characteristics
q
LSB
SUPPLY
= 0.085mAh •
PARAMETER
Logic Input Threshold, AL/CC, SCL,
SDA
Low Level Output Voltage, AL/CC, SDA I = 3mA
Input Leakage, AL/CC, SCL, SDA
Input Capacitance, AL/CC, SCL, SDA
Minimum Charge Complete (CC) Pulse
Width
Maximum SCL Clock Frequency
Bus Free Time Between Stop/Start
Minimum Repeated Start Setup Time
Minimum Hold Time (Repeated)
Start Condition
Minimum Setup Time for Stop
Condition
Minimum Data Setup Time Input
Minimum Data Hold Time Input
Data Hold Time Output
Data Output Fall Time
= I
SENSE +
t
SDA
SCL
HD, STA
CONDITION
128
M
START
+ I
SENSE –
t
SU, DAT
Figure 1. Definition of Timing on I
CONDITIONS
V
(Note 7)
(Notes 6, 7)
t
t
IN
HD, DATO,
HD, DATI
= V
A
= 25°C. (Note 2)
SENSE +
The
/2
REPEATED START
l
CONDITION
denotes the specifications which apply over the full operating
See Choosing Coulomb Counter Prescaler M section for more information.
Note 5: Deviation of q
and does not include long-term sense resistor aging. See the Internal
Sense Resistor section for more information.
Note 6: C
Note 7: Guaranteed by design, not subject to test.
Note 8: Value decreases if exposed pad is soldered to large copper area.
See Power Dissipation section for more information.
t
SU, STA
1mAh = 3.6A • s = 3.6C (Coulomb), 0.085mAh = 306mC.
t
HD, STA
B
= capacitance of one bus line in pF (10pF ≤ C
2
C Bus
t
SU, STO
l
l
l
l
l
l
l
l
l
l
l
l
l
LSB
0.3 • V
20 + 0.1 • C
from its nominal value. Data is for a new device
t
of
CONDITION
MIN
400
0.3
STOP
SENSE +
B
t
BUF
TYP
900
CONDITION
LTC2941-1
START
29411 F01
0.7 • V
B
MAX
≤ 400pF).
600
600
600
100
300
0.4
1.3
0.9
10
1
1
0
SENSE +
UNITS
29411f

kHz
µA
pF
µs
µs
ns
ns
ns
ns
µs
µs
ns
V
V

Related parts for LTC2941IDCB-1#TRPBF