LTC2941IDCB-1#TRPBF Linear Technology, LTC2941IDCB-1#TRPBF Datasheet - Page 9

no-image

LTC2941IDCB-1#TRPBF

Manufacturer Part Number
LTC2941IDCB-1#TRPBF
Description
IC FUEL/GAS GAUGE LI-ION 1A 6DFN
Manufacturer
Linear Technology
Datasheet

Specifications of LTC2941IDCB-1#TRPBF

Function
Fuel, Gas Gauge/Monitor
Battery Type
Lithium-Ion (Li-Ion)
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
6-WFDFN Exposed Pad
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
LTC2941IDCB-1#TRPBFLTC2941IDCB-1
Manufacturer:
LT
Quantity:
10 000
Company:
Part Number:
LTC2941IDCB-1#TRPBFLTC2941IDCB-1#PBF/CD
Manufacturer:
LT
Quantity:
183
Company:
Part Number:
LTC2941IDCB-1#TRPBFLTC2941IDCB-1#TRMPBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Company:
Part Number:
LTC2941IDCB-1#TRPBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
applicaTions inFormaTion
Bit A[5] is set if the LTC2941-1’s accumulated charge over-
flows or underflows the combined total in registers C and D.
Note that the counting process does not roll over, but simply
stops at FFFFh or 0000h until the direction is reversed.
The LTC2941-1 includes a battery undervoltage monitor,
which sets bit A1 if the limit is exceeded. Limits are selected
in the control register.
The undervoltage lockout (UVLO) bit A[0] is set if, dur-
ing operation, the voltage on SENSE
without reaching the POR level. The analog parts of the
coulomb counter are switched off while the digital register
values are retained. After recovery of the supply voltage
the coulomb counter resumes integrating with the stored
value in the accumulated charge registers (C, D) but it has
missed any charge flowing while V
The hard coded bit A[7] of the status register enables the
host to distinguish the LTC2941-1 from the pin compat-
ible LTC2942-1, allowing the same software to be used
with both devices.
Control Register (B)
The operation of the LTC2941-1 can be controlled by
programming the control register at address 01h. Table 3
shows the organization of the 8-bit control register B[7:0]
Table 3. Control Register B
B[7:6] V
B[5:3] Prescaler M Sets coulomb counter prescaling
B[2:1] AL/CC
B[0] Shutdown
BIT
NAME
Configure
BAT
Alert
OPERATION
[11] Threshold Value = 3.0V.
[10] Threshold Value = 2.9V.
[01] Threshold Value = 2.8V.
[00] V
factor M between 1 and 128.
Default is 128.
M = 2
Configures the AL/CC pin.
[10] Alert Mode.
Alert functionality enabled.
Pin becomes logic output.
[01] Charge Complete Mode.
Pin becomes logic input and accepts
“charge complete” signal (e.g., from
a charger) to set accumulated charge
Register to FFFFh.
[00] AL/CC pin disabled.
[11] Not allowed.
Shut down analog section to reduce
I
SUPPLY
(4 • B[5] + 2 • B[4] + B[3])
BAT
.
Alert Off.
SENSE +
+
.
drops below 2.7V
< 2.7V.
DEFAULT
[111]
[00]
[10]
[0]
Power Down B[0]
Programming the last bit B[0] of the control register to 1
sets the analog parts of the LTC2941-1 in power down and
the current consumption drops typically below 1µA. All
analog circuits are disabled while the values in the registers
are retained. Note that any charge flowing while B[0] is 1
is not measured and the charge information below 1LSB
of the accumulated charge register is lost.
Alert/Charge Complete Configuration B[2:1]
The AL/CC pin is a dual function pin configured by the
control register. By setting bits B[2:1] to [10] (default) the
AL/CC pin is configured as an alert pin following the SMBus
protocol. In this alert mode the AL/CC pin is a digital output
and is pulled low if one of the measured quantities exceeds
its high or low threshold or if the an overflow/underflow
occurs in the accumulated charge registers C and D. An
alert response procedure started by the master resets the
alert at the AL/CC pin. For further information see the Alert
Response Protocol section.
Setting the control bits B[2:1] to [01] configures the AL/CC
pin as a digital input. In this mode, a high input on the
AL/CC pin communicates to the LTC2941-1 that the battery
is full and the accumulated charge is set to its maximum
value FFFFh. Coulomb counting starts when the AL/CC pin
returns to low level.
If neither the alert nor the charge complete functionality
is desired, bits B[2:1] should be set to [00]. The AL/CC
pin is then disabled and should be tied to GND. Avoid set-
ting B[2:1] to [11] as it enables the alert and the charge
complete modes simultaneously.
Choosing Coulomb Counter Prescaler ‘M’ B[5:3]
To use as much of the range of the accumulated charge
register as possible the prescaler factor M is chosen based
on battery capacity Q
M can be set to 1, 2 ,4, 8,... 128 by programming B[5:3]
of the control register as M = 2
M
128
2
16
• .
Q
0 085
BAT
BAT
mAh Ah
:
=
23
(4 • B[5] + 2 • B[4] + B[3])
LTC2941-1
Q
BAT
29411f

.

Related parts for LTC2941IDCB-1#TRPBF