CS5463-ISZ Cirrus Logic Inc, CS5463-ISZ Datasheet - Page 23

IC ENERGY METERING 1PHASE 24SSOP

CS5463-ISZ

Manufacturer Part Number
CS5463-ISZ
Description
IC ENERGY METERING 1PHASE 24SSOP
Manufacturer
Cirrus Logic Inc
Datasheet

Specifications of CS5463-ISZ

Package / Case
24-SSOP
Input Impedance
30 KOhm
Measurement Error
0.1%
Voltage - I/o High
0.8V
Voltage - I/o Low
0.2V
Current - Supply
2.9mA
Voltage - Supply
4.75 V ~ 5.25 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Meter Type
Single Phase
Output Voltage Range
2.4 V to 2.6 V
Input Voltage Range
2.4 V to 2.6 V
Input Current
25 nA
Power Dissipation
500 mW
Operating Temperature Range
- 40 C to + 85 C
Mounting Style
SMD/SMT
Input Voltage
5.25V
No. Of Outputs
3
Power Dissipation Pd
500mW
Supply Voltage Range
3.3V To 5V
No. Of Pins
24
Filter Terminals
SMD
Supply Voltage Min
3.3V
Rohs Compliant
Yes
Frequency
20GHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
598-1553 - BOARD EVAL & SOFTWARE CS5463 ADC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
598-1096-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS5463-ISZ
Manufacturer:
CIRRUS
Quantity:
39
Part Number:
CS5463-ISZ
Manufacturer:
CS
Quantity:
1 045
Part Number:
CS5463-ISZ
Manufacturer:
CIRRUS
Quantity:
20 000
Part Number:
CS5463-ISZ
0
Part Number:
CS5463-ISZR
Manufacturer:
CYPRESS
Quantity:
1 001
Part Number:
CS5463-ISZR
Manufacturer:
CIRRUS
Quantity:
20 000
5.16 Commands
All commands are 8 bits in length. Any command byte value that is not listed in this section is invalid. Commands
that write to registers must be followed by 3 bytes of data. Commands that read data can be chained with other com-
mands (e.g., while reading data, a new command can be sent which can execute during the original read). All com-
mands except register reads, register writes, and SYNC0 & SYNC1 will abort any currently executing commands.
5.16.1 Start Conversions
5.16.2 SYNC0 and SYNC1
The serial port can be initialized by asserting CS or by sending three or more consecutive SYNC1 commands fol-
lowed by a SYNC0 command. The SYNC0 or SYNC1 can also be sent while sending data out.
5.16.3 Power-up/Halt
If the device is powered-down, Power-Up/Halt will initiate a power on reset. If the part is already powered-on, all
computations will be halted.
5.16.4 Power-down and Software Reset
To conserve power the CS5463 has two power-down states. In stand-by state all circuitry, except the analog/digital
clock generators, is turned off. In the sleep state all circuitry, except the command decoder, is turned off. Bringing
the CS5463 out of sleep state requires more time than out of stand-by state, because of the extra time needed to
re-start and re-stabilize the analog oscillator.
DS678F2
Initiates acquiring measurements and calculating results. The device has two modes of acquisition.
B7
B7
B7
B7
1
1
1
1
SYNC
C3
S[1:0]
B6
B6
B6
B6
1
1
0
0
B5
B5
B5
B5
1
1
1
0
0 = Perform a single computation cycle
1 = Perform continuous computation cycles
0 = Last byte of a serial port re-initialization sequence.
1 = Used during reads and serial port initialization.
00 = Software Reset
01 = Halt and enter stand-by power saving state. This state allows quick power-on
10 = Halt and enter sleep power saving state.
11 = Reserved
Modes of acquisition/measurement
Power-down state
B4
B4
B4
B4
S1
0
1
0
B3
C3
B3
B3
B3
S0
1
0
B2
B2
B2
B2
0
1
0
0
B1
B1
B1
B1
0
1
0
0
SYNC
B0
B0
B0
B0
0
0
0
CS5463
23

Related parts for CS5463-ISZ