MAX16816ATJ+ Maxim Integrated Products, MAX16816ATJ+ Datasheet - Page 28

IC LED DRIVR HIGH BRIGHT 32-TQFN

MAX16816ATJ+

Manufacturer Part Number
MAX16816ATJ+
Description
IC LED DRIVR HIGH BRIGHT 32-TQFN
Manufacturer
Maxim Integrated Products
Type
HBLED Driverr
Datasheet

Specifications of MAX16816ATJ+

Topology
PWM, SEPIC, Step-Down (Buck), Step-Up (Boost)
Number Of Outputs
1
Internal Driver
Yes
Type - Primary
Automotive
Type - Secondary
High Brightness LED (HBLED)
Frequency
125kHz ~ 500kHz
Voltage - Supply
5.5 V ~ 76 V
Mounting Type
Surface Mount
Package / Case
32-TQFN Exposed Pad
Operating Temperature
-40°C ~ 125°C
Internal Switch(s)
Yes
Efficiency
90%
Low Level Output Current
76 mA
High Level Output Current
67 mA
Operating Supply Voltage
5.5 V to 76 V
Maximum Supply Current
4.5 mA
Maximum Power Dissipation
2758 mW
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Output
-
Current - Output / Channel
-
Lead Free Status / Rohs Status
 Details
The MAX16816 can only transmit data to the master
when the master issues read time slots.
All read time slots must be a minimum of 60µs in dura-
tion with a minimum of a 1µs recovery time between
slots. A read time slot is initiated by the master device
pulling the 1-Wire bus low for a minimum of 1µs and
then releasing it (Figure 9). After the master initiates the
read time slot, the MAX16816 will transmit a ‘1’ or a ‘0’
Programmable Switch-Mode LED Driver
with Analog-Controlled PWM Dimming
Figure 9. 1-Wire Read Time Slot
28
______________________________________________________________________________________
V
IL
/ V
V
OH
0V
OL
RESISTOR
t
RL
Read Time Slots
t
MSR
SAMPLING
WINDOW
MASTER
MASTER
t
SLOT
on the bus. The MAX16816 transmits a ‘1’ by leaving
the bus high and transmits a ‘0’ by pulling the bus low.
When transmitting a ‘0’, the MAX16816 will release the
bus before the end of the time slot, and the bus will be
pulled back to its high idle state by the pullup resistor.
Output data from the MAX16816 is valid for 15µs after the
falling edge that initiated the read time slot. Therefore, the
master must release the bus and then sample the bus
state within 15µs from the start of the slot.
t
REC
MAX16816