CAT9552HV6I-GT2 ON Semiconductor, CAT9552HV6I-GT2 Datasheet - Page 7

IC LED DRIVER LINEAR 24-TQFN

CAT9552HV6I-GT2

Manufacturer Part Number
CAT9552HV6I-GT2
Description
IC LED DRIVER LINEAR 24-TQFN
Manufacturer
ON Semiconductor
Type
Linear (I²C Interface)r
Datasheet

Specifications of CAT9552HV6I-GT2

Topology
PWM
Number Of Outputs
16
Internal Driver
Yes
Type - Primary
LED Blinker
Frequency
400Hz
Voltage - Supply
2.3 V ~ 5.5 V
Mounting Type
Surface Mount
Package / Case
24-TFQFN Exposed Pad
Operating Temperature
-40°C ~ 85°C
Current - Output / Channel
25mA
Internal Switch(s)
Yes
Number Of Segments
16
Low Level Output Current
25 mA
Operating Supply Voltage
2.3 V to 5.5 V
Maximum Supply Current
550 uA
Maximum Power Dissipation
1 W
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Output
-
Efficiency
-
Lead Free Status / Rohs Status
 Details
FUNCTIONAL DESCRIPTION
The CAT9552 is a 16-channel I/O bus expander that
provides a pair of programmable LED blinkers,
controlled through an I
CAT9552 supports the I
protocol. This Inter-Integrated Circuit Bus protocol
defines any device that sends data to the bus to be a
transmitter and any device receiving data to be a
receiver. The transfer is controlled by the Master
device which generates the serial clock and all
START and STOP conditions for bus access. The
CAT9552 operates as a Slave device. Both the
Master device and Slave device can operate as either
transmitter or receiver, but the Master device controls
which mode is activated.
I
The features of the I
follows:
(1) Data transfer may be initiated only when the bus
(2) During a data transfer, the data line must remain
START and STOP Conditions
The START Condition precedes all commands to the
device, and is defined as a HIGH to LOW transition of
© 2010 SCILLC. All rights reserved
Characteristics subject to change without notice
2
C Bus Protocol
is not busy.
stable whenever the clock line is high. Any
changes in the data line while the clock line is
high will be interpreted as a START or STOP
condition (Figure 2).
SDA
SCL
2
2
C bus protocol are defined as
C compatible serial interface.
2
C Bus data transmission
START CONDITION
Figure 3. CAT9552 Slave Address
1
Figure 2. Start/Stop Timing
1
FIXED
SLAVE ADDRESS
0
0
7
PROGRAMMABLE
A2
SELECTABLE
SDA when SCL is HIGH. The CAT9552 monitors the
SDA and SCL lines and will not respond until this
condition is met.
A LOW to HIGH transition of SDA when SCL is HIGH
determines the STOP condition. All operations must
end with a STOP condition.
Device Addressing
After the bus Master sends a START condition, a
slave address byte is required to enable the CAT9552
for a read or write operation. The four most significant
bits of the slave address are fixed as binary 1100
(Figure 3). The CAT9552 uses the next three bits as
address bits.
The address bits A2, A1 and A0 are used to select
which device is accessed from maximum eight
devices on the same bus. These bits must compare to
their hardwired input pins. The 8th bit following the 7-
bit slave address is the R/W bit that specifies whether
a read or write operation is to be performed. When
this bit is set to “1”, a read operation is initiated, and
when set to “0”, a write operation is selected.
Following the START condition and the slave address
byte, the CAT9552 monitors the bus and responds
with an acknowledge (on the SDA line) when its
address matches the transmitted slave address. The
CAT9552 then performs a read or a write operation
depending
HARDWARE
A1
A0
R/W
STOP CONDITION
on
the
state
of
the
Doc. No. MD-9005 Rev D
CAT9552
R/W
bit.