LDP10WH10-A Panduit Corp, LDP10WH10-A Datasheet - Page 53

no-image

LDP10WH10-A

Manufacturer Part Number
LDP10WH10-A
Description
RACEWAY 1CHAN LG AD WH(10=10')
Manufacturer
Panduit Corp
Series
Pan-Way™r
Datasheet

Specifications of LDP10WH10-A

Wire Duct Type
Solid (Raceway), Single Channel
Height
0.860" (21.80mm)
Length
10.00' (3.05m)
Width
1.51" (38.4mm)
Mounting Type
Adhesive
Features
Attached Latching Lid
Color
White
Quick Wire Fill Capacities for T-70 Raceway
This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary according to
the wire installation methods, straightness of wires, etc.
SPEC = 40% wire fill — The recommended design in cable capacity,
leaves room for future moves, adds and changes.
2a.
2b.
5a.
5b.
1.
3.
4.
T-70: No devices.
T-70: Power and data using the Three-
Sided Hanging Box and Device Bracket.
T-70: Data only (Screw-on Faceplates).
T-70: Data only (Snap-on Faceplates).
T-70: Power and data using the
W
ORKSTATION
Wirefill #1: Raceway with
Raceway Type & Configuration
CR-SR-T70-WireFill1
A = 5.15 in
no devices.
O
UTLET
Communication Faceplates.
Wirefill #4: Data only using
Horizontal Sloped Snap-on
C
ENTER
2
A = 4.71 in
Offset Box.
2
Area
5.15
1.72
3.67
4.71
3.12
(in²)
Fill
.86
.91
For service and technical support, call 800-777-3300 (outside the U.S. and Canada, see back cover).
14 AWG 12 AWG 10 AWG
MAX
.105
24
14
14
(UL Temp Rise Test)
Electrical Cables
Wirefill #2: Power and data using
Three-Sided Hanging Box and
THHN/T90
A = .86 in
a
MAX
FILL
.122
20
11
11
Device Bracket.
MAX
Wirefill #5: Power and data using the W
.153
15
2
7
7
Data Grade Cable Data Grade Cable
SPEC
MAX for Data = 60% wire fill — The maximum cable quantity
based on cable interweaving and packing factors.
MAX for Power wire fill — The maximum of electrical cables
based on UL temperature rise test.
(40%)
24 AWG/UTP CM
A = 1.72 in
55
19
39
50
33
9
9
Cat 5e (4pr)
DIA. = .217
A = .91 in
O
FILL
UTLET
(60%)
MAX
b
83
14
28
59
76
14
50
C
2
2
ENTER
SPEC
(40%)
24 AWG/UTP CM
41
14
29
38
25
7
7
A = 3.12 in
DIA. = .250
a
Cat 6 (4pr)
Offset Box.
FILL
(60%)
MAX
62
10
21
44
57
11
38
2
ORKSTATION
Wirefill #3: Data only using
Communication Faceplates.
Vertical Sloped Screw-on
SPEC
(40%)
Coax Cable
b
DIA. = .275
27
19
25
17
5
9
5
RG6
FILL
A = 3.67 in
(60%)
MAX
41
14
29
37
25
7
7
Fiber Optic Cable
SPEC
(40%)
86
14
29
67
83
15
52
2
DIA. = .175
2 Strand
FILL
(60%)
MAX
129
101
125
21
43
23
78
F13
Faceplates,
Furniture
LD Profile
Overview
Selection
Technical
Ultimate
Labeling
Twin-70
Boxes &
System
System
Office
Outlet
Quick
Guide
TG-70
Index
Cove
T130
T-70
T-45
Pole
Info
ID
&