TLE6230GP Infineon Technologies, TLE6230GP Datasheet - Page 10

IC SW SMART OCTAL LOWSIDE PDSO36

TLE6230GP

Manufacturer Part Number
TLE6230GP
Description
IC SW SMART OCTAL LOWSIDE PDSO36
Manufacturer
Infineon Technologies
Type
Low Sider
Datasheet

Specifications of TLE6230GP

Input Type
SPI
Number Of Outputs
8
On-state Resistance
800 mOhm
Current - Peak Output
1.5A
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 150°C
Mounting Type
Surface Mount
Package / Case
DSO-36
Switch Type
Low Side
Power Switch Family
TLE6230
Input Voltage
-0.3 to 7V
Power Switch On Resistance
800mOhm
Output Current
1A
Mounting
Surface Mount
Supply Current
1mA
Package Type
DSO
Operating Temperature (min)
-40C
Operating Temperature (max)
150C
Operating Temperature Classification
Automotive
Pin Count
38
Power Dissipation
3300W
Packages
PG-DSO-36
Thermal Class
Heatslug down
Id Nom
8 x 0.5 A
Channels
8.0
Comment
relay driver and general purpose
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Output / Channel
-
Lead Free Status / Rohs Status
Compliant
Other names
SP000012169
SP000691114
TLE6230GP
TLE6230GPNT
TLE6230GPT
TLE6230GPT
TLE6230GPTR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TLE6230GP
Manufacturer:
INFINEON
Quantity:
1 210
Part Number:
TLE6230GP
Manufacturer:
INFINEON
Quantity:
804
Part Number:
TLE6230GP
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
A definite distinction between open load and short to ground is guaranteed by design.
The standard way of obtaining diagnostic information is as follows:
Clock in serial information into SI pin and wait approximately 150 µs to allow the outputs toset-
tle. Clock in the identical serial information once again - during this process the data coming
out at SO contains the bit combinations representing the diagnosis conditions as described in
figure 1.
By means of the control byte it is possible either to:
a) Serial Control of Outputs
Control byte is set to FFhex: Data byte will be accepted. The outputs will be switched ON or
OFF according to the information of the data byte and the parallel inputs (Channel 1 to 4 be-
cause of AND operation).
All other control words except the one for 'Diagnosis Only = 00hex' will also be accepted as a
valid control word and the data will be accepted.
Example: HLLHLHLH DDDDDDDD: Outputs will switch according to the data bits.
b) Diagnosis Only
Control byte is set to 00hex: Data byte will be ignored. Diagnostic information can be read out
at any time with no change of the switching conditions. Only 00hex means 'Diagnosis Only'.
V2.3
HHHHHHHH LHLHHLLL
LLLLLLLL XXXXXXXX
1
1 2
Control Byte
or b) purely get diagnostic information without changing the state of the outputs.
4 4
4 4
Control Byte
2
a) control the eight outputs according to the data byte, as well as being able to read the
4 4 1
44 1
diagnostic information
3
3
4 4
Data Byte
4 4
Data Byte
2
2
44
44
3
3
: Serial input information
: Serial input information
Page
10
Data Sheet TLE 6230 GP
18. Nov. 2009

Related parts for TLE6230GP