BTS611L1 Infineon Technologies, BTS611L1 Datasheet - Page 5

no-image

BTS611L1

Manufacturer Part Number
BTS611L1
Description
SWITCH DUAL CHAN PWR TO-220AB7
Manufacturer
Infineon Technologies
Series
PROFET®r
Type
High Sider
Datasheet

Specifications of BTS611L1

Input Type
Non-Inverting
Number Of Outputs
2
On-state Resistance
160 mOhm
Current - Output / Channel
2.3A
Current - Peak Output
7.5A
Voltage - Supply
5 V ~ 34 V
Operating Temperature
-40°C ~ 150°C
Mounting Type
Through Hole
Package / Case
TO-220AB-7 (Bent Leads)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
BTS611L1IN
SP000011269

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BTS611L1
Manufacturer:
infineon
Quantity:
1 500
Part Number:
BTS611L1
Manufacturer:
infineon
Quantity:
5 510
Part Number:
BTS611L1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
BTS611L1 E3128A
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Company:
Part Number:
BTS611L1 E3128A
Quantity:
4 800
Part Number:
BTS611L1 E3230
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
BTS611L1-7-2
Manufacturer:
SIEMENS
Quantity:
5 000
Part Number:
BTS611L1-E3128
Manufacturer:
SIEMENS
Quantity:
6 000
Part Number:
BTS611L1E3128A
Manufacturer:
INFINEON
Quantity:
1 230
Parameter and Conditions,
at T
Protection Functions
Initial peak short circuit current limit (pin 4 to 1
or 7)
Repetitive short circuit shutdown current limit
Output clamp (inductive load switch off)
at V
Thermal overload trip temperature
Thermal hysteresis
Reverse battery (pin 4 to 2)
Reverse battery voltage drop
Diagnostic Characteristics
Open load detection current
Open load detection voltage
Internal output pull down
9
10
11)
Semiconductor Group
)
I
(pin 1
) Requires 150
L
(on-condition)
T
j
= -1.8 A, each channel
Integrated protection functions are designed to prevent IC destruction under fault conditions described in the
data sheet. Fault conditions are considered as "outside" normal operating range. Protection functions are not
designed for continuous repetitive operation.
diode has to be limited by the connected load. Note that the power dissipation is higher compared to normal
operating conditions due to the voltage drop across the intrinsic drain-source diode. The temperature
protection is not active during reverse current operation! Input and Status currents have to be limited (see
max. ratings page 2 and circuit page 8).
External pull up resistor required for open load detection in off state.
= 25 °C, V
OUT
j
= T
or
= V
jt
7 to 2), V
(see timing diagrams, page 11)
bb
bb
- V
= 12 V unless otherwise specified
ON(CL)
resistor in GND connection. The reverse load current through the intrinsic drain-source
OUT
=5 V, T
9)
11
10
each channel
(V
j
) (off-condition)
=-40..150°C
)
out
> V
T
T
j
bb
=25 ..150°C:
j
=-40..150°C:
T
)
I
j
T
T
L
T
=+150°C:
T
j
= 40 mA: V
=150 °C: -V
j
j
=-40 °C
j
=-40°C:
=25°C:
5
:
I
I
T
-V
I
V
R
L(SCp)
L(SCr)
L (OL)
Symbol
jt
T
ON(CL)
OUT(OL)
O
bb
ON(rev)
jt
PROFET ® BTS611L1
150
min
5.5
4.5
2.5
41
10
10
--
--
--
--
2
4
Values
610
9.5
7.5
4.5
typ
47
10
10
--
--
--
--
4
3
2003-Oct-01
max
200
150
13
11
53
32
30
--
--
--
--
7
4
Unit
mV
mA
k
°C
A
A
V
K
V
V

Related parts for BTS611L1