AMIS30623C623AG ON Semiconductor, AMIS30623C623AG Datasheet - Page 22

IC MOTOR DVR MICROSTP LIN 32NQFP

AMIS30623C623AG

Manufacturer Part Number
AMIS30623C623AG
Description
IC MOTOR DVR MICROSTP LIN 32NQFP
Manufacturer
ON Semiconductor
Type
Stepper Motor Driverr
Datasheet

Specifications of AMIS30623C623AG

Applications
Stepper Motor Driver
Number Of Outputs
1
Current - Output
800mA
Voltage - Supply
6.5 V ~ 29 V
Operating Temperature
-40°C ~ 165°C
Mounting Type
Surface Mount
Package / Case
32-VSQFP
Product
Stepper Motor Controllers / Drivers
Operating Supply Voltage
5 V
Supply Current
10 mA
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Load
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AMIS30623C623AG
Manufacturer:
ON Semiconductor
Quantity:
70
Part Number:
AMIS30623C623AG
Manufacturer:
ON Semiconductor
Quantity:
10 000
is received (this valid frame can be addressed to another
slave).
Thermal Shutdown Mode
<SoftStop> command and goes to motor shutdown
mode (see Figure 14: State Diagram Temperature
Management).
The circuit will return to normal mode if a valid LIN frame
When thermal shutdown occurs, the circuit performs a
− <Tinfo> = “00”
− <TW> = ‘0’
− <TSD> = ‘0’
− <Tinfo> = “01”
− <TW> = ‘0’
− <TSD> = ‘0’
Normal Temp.
Low Temp.
T° < Tlow
T° > Tlow
T° < Ttw &
LIN frame:
GetStatus or
GetFullStatus
Figure 14. State Diagram Temperature Management
T° > Ttw
T° > Ttw
− <Tinfo> = “10”
− <TW> = ‘1’
− <TSD> = ‘0’
− <Tinfo> = “00”
− <TW> = ‘1’
− <TSD> = ‘0’
− <Tinfo> = “00”
− <TW> = ‘1’
− <TSD> = ‘1’
− Motor shutdown
Thermal warning
http://onsemi.com
(motion disabled)
Post thermal
Post thermal
shutdown 2
warning
22
T° < Ttw
Temperature Management
thresholds and one shutdown level, as illustrated in the state
diagram and illustration of Figure 14: State Diagram
Temperature Management below. The only condition to
reset flags <TW> and <TSD> (respectively thermal warning
and thermal shutdown) is to be at a temperature lower than
Ttw and to get the occurrence of a GetStatus or a
GetFullStatus LIN frame.
The AMIS−30623 monitors temperature by means of two
T° < Ttw
T° > Ttsd
T° > Ttw
T° > Ttsd
− <Tinfo> = “11”
− <TW> = ‘1’
− <TSD> = ‘1’
−SoftStop if
− Motor shutdown
− <Tinfo> = “10”
− <TW> = ‘1’
− <TSD> = ‘1’
− Motor shutdown
Thermal shutdown
motion ongoing
(motion disabled)
(motion disabled)
Post thermal
shutdown 1
T° < Ttsd