MCZ33800EK Freescale Semiconductor, MCZ33800EK Datasheet - Page 25

no-image

MCZ33800EK

Manufacturer Part Number
MCZ33800EK
Description
IC ENGINE CTRL SW/DVR 54-SOIC
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of MCZ33800EK

Applications
Automotive
Current - Supply
10mA
Voltage - Supply
5 V ~ 36 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
54-SOIC (7.5mm Width) Exposed Pad, 54-eSOIC, 54-HSOIC
Product
Fan / Motor Controllers / Drivers
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCZ33800EK
Manufacturer:
Freescale Semiconductor
Quantity:
135
Part Number:
MCZ33800EK
Manufacturer:
FREESCALE
Quantity:
2 430
Part Number:
MCZ33800EK
Manufacturer:
FREESCALE
Quantity:
2 430
Part Number:
MCZ33800EK
Manufacturer:
FREESCALE
Quantity:
20 000
Table 12. OSS SPI Control Commands and Response
ON /OFF CONTROL COMMAND
bit serial stream of data is entered into the SI pin. The first 8-
bits of the control word are used to identify the on / off
command and the remaining 8-bits are used to turn ON or
OFF the specific output driver. When commanding an output
ON or OFF, the Most Significant Bit (MSB) is sent and
received first. Bit 7 corresponds to output 8 down to bit 0
which corresponds to output 1.
OPEN LOAD CURRENT ENABLE COMMAND
disable the open load detect pull-down current. This feature
allows the device to be used in LED applications. On power
up reset (POR) or the RESET command the pull-down
current sources are disabled. To enable the open load
current source, the user must program the Open Load
Current Disable Control register with logic[1]. Open load
Analog Integrated Circuit Device Data
Freescale Semiconductor
OSS ON/OFF Command
0 = off, 1 = on
Open Load Current Enable
0 = disable, 1 = enable
Shutdown / Retry from V
Voltage
0 = shutdown, 1 = retry
Shutdown / Retry from Short
Circuit
0 = shutdown, 1 = retry
TLim Command
0 = disable, 1 = enable
Fault Timer Command
0 = Fault Timer Disabled
1 = Fault Timer Enabled
Parallel
Outputs(7&8,5&6,3&4,1&2)
Parallel Input Pin Enable
0 = Individual Control, PX enabled
1 = Parallel Control, PX disabled
AND/OR Control
0 = PX Pin OR with SPI
1 = PX Pin AND with SPI
Next SO Response (Message 1)
0 = No Fault, 1 = Fault
To program the 8 outputs of the 33800 ON or OFF, a 16-
The Open Load Enable Command is provided to enable or
Command
PWR
Over
OvrVlt
,TLim
CAL
15
Flt
or
0
0
0
0
0
0
0
0
Reset Fault
Control Address
14
0
0
0
0
0
0
0
1
Statu
sPW
M6
13
0
0
0
1
1
1
1
0
Statu
Fault
sPW
M5
12
0
1
1
0
0
1
1
0
Fault
Statu
sPW
M4
11
1
0
1
0
1
0
1
0
Statu
Fault
sPW
M3
10
X
X
X
X
X
X
X
X
faults may not be reported with the pull-down current source
disabled.
OVER-VOLTAGE SHUTDOWN/RETRY COMMAND
user to select the fault strategy for the outputs. The over-
voltage control bit sets the operation of the outputs when
returning from over-voltage. Setting the over-voltage bit to
logic[0] will force all outputs to remain OFF when V
returns to normal level. Setting the over-voltage bit to logic[1]
will command outputs to resume their previous state when
V
TLIM COMMAND, TIMER COMMAND
short circuit protection strategy of the Octal Serial Switch
output drivers.
event of a short circuit. The TLim protection circuit uses the
PWR
Statu
Fault
sPW
M2
The Over Voltage Shutdown/Retry Command allows the
The TLim and Timer commands are used to enhance the
The Timer protection scheme uses a low duty cycle in the
9
X
X
X
X
X
X
X
X
returns to normal level.
Statu
Fault
sPW
M1
X
X
X
X
X
X
X
X
8
Output
sOUT
Statu
Fault
7&8
7
0
0
1
1
1
1
0
0
8
Output
sOUT
Statu
Fault
5&6
Command Bits
6
0
0
1
1
1
1
0
0
7
LOGIC COMMANDS AND REGISTERS
Output
sOUT
Statu
Fault
3&4
FUNCTIONAL DEVICE OPERATION
5
0
0
1
1
1
1
0
0
6
Output
sOUT
Statu
Fault
1&2
4
0
0
1
1
1
1
0
0
5
P7 en
sOUT
Fault
Statu
3
0
0
1
1
1
1
0
0
4
P5 en
sOUT
Statu
Fault
2
0
0
1
1
1
1
0
0
3
P3 en
sOUT
Statu
Fault
1
0
0
1
1
1
1
0
0
2
PWR
P1 en
sOUT
Statu
Fault
33800
0
0
0
1
1
1
1
0
0
1
25