Specifications of SA56004EDP,118

Package / Case
8-TSSOP
Output Type
I²C™/SMBus™
Function
Temp Monitoring System (Sensor)
Topology
ADC (Sigma Delta), Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Supply Voltage (max)
5.5 V
Supply Voltage (min)
3 V
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Supply Current
1 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
568-3615 - DEMO BOARD I2C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
568-3338-2
935274567118
SA56004EDP-T
NXP Semiconductors
Table 14.
[1]
[2]
SA56004X_5
Product data sheet
Byte
Bit
Value
POR default RTOHB = RTOLB = 00h.
POR default RTOLB = 00h.
High byte (read/write address 11h)
sign
D7
RTOHB, RTOLB - Remote temperature offset registers
7.8.10 One-shot register
7.8.7 Programmable offset register (remote only)
7.8.8 ALERT mode register (AM)
7.8.9 Other registers
D6
64
Table 13.
[1]
Table 15.
Read and write address BFh.
D[7:1] is not defined and defaults to logic 0.
D0: The ALERT output is in interrupt mode when this bit is LOW. The ALERT output is in
comparator mode when this bit is HIGH.
The Manufacturers ID register has a default value A1h (1010 0001) and a read address
FEh.
The Die Revision Code register has a default value 00h (0000 0000) and read address
FFh. This register will increment by 1 every time there is a revision to the die.
The one-shot register is used to initiate a single conversion and comparison cycle when
the device is in the standby mode; upon completion of the single conversion cycle, the
device returns to the standby mode. It is not a data register; it is the write operation that
causes the one-shot conversion. The data written to this register is not stored; an FFh
value will always be read from this register. To initiate a one-shot operation, send a
standard write command with the command byte of 0Fh (One-Shot Write Address).
Byte
Bit
Value
Bit
Value
D5
32
POR default TH = 0Ah (10 C).
D4
16
TH - T_CRIT hysteresis register
AM - ALERT mode register
D7
D3
Single high byte (read/write address 21h)
0
8
D7
-
D2
[1]
4
D6
0
Rev. 05 — 22 May 2008
D6
D1
2
-
Digital temperature sensor with overtemperature alarms
D5
0
D0
1
D5
-
Low byte (read/write address 12h)
0.5
D7
D4
0
0.25
D4
16
D6
D3
0
0.125
D5
[1]
D3
8
D4
D2
0
0
D2
4
D3
0
SA56004X
D1
0
[2]
© NXP B.V. 2008. All rights reserved.
D2
0
D1
2
ALERT mode
D1
0
D0
11 of 36
D0
1
D0
0

Related parts for SA56004EDP,118