DS620U+ Maxim Integrated Products, DS620U+ Datasheet - Page 14

IC THERMOMETER/STAT DIG 8MSOP

DS620U+

Manufacturer Part Number
DS620U+
Description
IC THERMOMETER/STAT DIG 8MSOP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS620U+

Function
Thermometer, Thermostat
Topology
ADC (Sigma Delta), Register Bank
Sensor Type
Internal
Sensing Temperature
-55°C ~ 125°C
Output Type
I²C™/SMBus™
Output Alarm
No
Output Fan
No
Voltage - Supply
1.7 V ~ 3.5 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-MSOP Exposed Pad, 8-HMSOP, 8-eMSOP
Temperature Threshold
Programmable
Full Temp Accuracy
+/- 0.5 C
Digital Output - Bus Interface
2-Wire, SMBus
Digital Output - Number Of Bits
10 bit to 13 bit
Supply Voltage (max)
3.5 V
Supply Voltage (min)
1.7 V
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Supply Current
800 uA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
WRITING THE 1SHOT BIT COMMAND SEQUENCE
Configuring from continuous mode to 1SHOT mode.
MASTER
MODE
BUS
RX
RX
RX
RX
RX
RX
RX
RX
RX
RX
RX
TX
TX
TX
TX
TX
TX
TX
TX
TX
TX
TX
TX
TX
TX
TX
TX
TX
TX
DS620
MODE
RX
RX
RX
RX
RX
RX
RX
RX
TX
TX
TX
TX
TX
RX
RX
RX
RX
RX
RX
RX
RX
RX
RX
TX
TX
TX
TX
TX
TX
<address, 0>
<address, 0>
(MSB FIRST)
<address, 0>
<address, 0>
<address, 0>
xxxxxxx1b
xxxxxxx1b
START
START
STOP
START
START
START
ACK
ACK
ACK
ACK
ACK
DATA
48h
22h
ACK
ACK
ACK
ACK
ACK
ACK
ACh
51h
48h
DS620 generates acknowledge.
Bus master writes to the configuration register putting
the DS620 back in 1SHOT mode: 1SHOT = 1.
Bus master generates a repeated start condition.
Bus master sends DS620 address, R/W = 0.
DS620 generates acknowledge.
Master sends COPY DATA command to DS620 to
copy data in from SRAM memory to EEPROM memory.
DS620 generates acknowledge.
Bus master generates a repeated start condition.
Bus master sends DS620 address, R/W = 0.
DS620 generates acknowledge.
Bus master sends a STOP CONVERT command to
stop the DS620 from continuously converting
temperature. NOTE: Bus master should ensure that
EEPROM copy operation is complete before executing
the STOP CONVERT command by either waiting 10ms
from the time of the COPY DATA command or
checking the NVB bit in configuration register
DS620 generates acknowledge.
Bus master sends STOP condition to end
communication with DS620. (The bus master could
send a repeated start condition if additional
communication with the DS620 is desired.)
Bus master initiates a START condition.
Bus master sends DS620 address, R/W = 0.
DS620 generates acknowledge bit.
Master sends START CONVERT command to DS620
to start temperature conversions.
DS620 generates acknowledge bit and begins
conversions.
Bus master generates a repeated start condition.
Bus master sends DS620 address, R/W = 0.
DS620 generates acknowledge.
Bus master sends the address location of the MSb of
the configuration register (contains the 1SHOT bit).
This writes to the SRAM location corresponding the
EEPROM location.
DS620 generates acknowledge.
Bus master writes to the configuration register putting
the DS620 in 1SHOT mode: 1SHOT = 1.
DS620 generates acknowledge.
Bus master generates a repeated start condition.
Bus master sends DS620 address, R/W = 0.
DS620 generates acknowledge.
Master sends COPY DATA command to DS620 to
copy data in from SRAM memory to EEPROM
memory.
14 of 15
COMMENTS
SEQUENCE
NUMBER
30
31
32
33
34
35
36
37
38
39
40
41
42
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
9

Related parts for DS620U+