DS1775R1+T&R Maxim Integrated Products, DS1775R1+T&R Datasheet - Page 8

IC THERMOM/STAT DIG 001 SOT-23-5

DS1775R1+T&R

Manufacturer Part Number
DS1775R1+T&R
Description
IC THERMOM/STAT DIG 001 SOT-23-5
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS1775R1+T&R

Function
Thermometer, Thermostat
Topology
ADC, Comparator, Register Bank
Sensor Type
Internal
Sensing Temperature
-55°C ~ 125°C
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
No
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
SOT-23-5, SC-74A, SOT-25
Full Temp Accuracy
+/- 3 C
Digital Output - Bus Interface
Serial (2-Wire)
Digital Output - Number Of Bits
12 bit
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Thermometer Resolution Configuration Table 5
Thermostat Setpoints Programming
The thermostat registers (T
accessed by setting the DS1775 data pointer to the 03h location, and to the 02h location for T
The format of the T
2’s complement representation of the temperature in °C. The user can program the number of bits (9, 10,
11, or 12) for each T
example, if the 9–bit mode is chosen the 3 least significant bits of T
thermostat comparator. The format for both T
for T
Thermostat Setpoint (T
TEMPERATURE/DATA RELATIONSHIPS
If the user does not wish to take advantage of the thermostat capabilities of the DS1775, the 24 bits can be
used for general storage of system data that need not be maintained following a power loss.
R1
0
0
1
1
MSb
2
S
OS
-1
-25.0625°C
+10.125°C
-10.125°C
is 80°C and for T
R0
TEMP
+0.5°C
0
1
0
1
+80°C
+75°C
-0.5°C
-55°C
+0°C
2
2
-2
6
OS
OS
and T
Thermometer Resolution
HYST
and T
2
2
OS
-3
HYST
5
is 75°C.
and T
OS
HYST
10-bit
11-bit
12-bit
registers is identical to that of the Thermometer register; that is, 12–bit
9-bit
/T
DIGITAL OUTPUT
0101 0000 0000 0000
0100 1011 0000 0000
0000 1010 0010 0000
0000 0000 1000 0000
0000 0000 0000 0000
1111 1111 1000 0000
1111 0101 1110 0000
1110 0110 1111 0000
1100 1001 0000 0000
HYST
HYST
that corresponds to the thermometer resolution mode chosen. For
2
2
(UNIT = °C)
-4
4
) can be programmed or read via the 2–wire interface. T
) Format Table 6
(Binary)
OS
8 of 14
and T
2
0
3
HYST
is shown in Table 6. The power–up default
2
0
2
OS
Max Conversion Time
and T
DIGITAL OUTPUT (Hex)
2
0
1
HYST
0.1875s
0.375s
0.75s
1.5s
will be ignored by the
0A20h
4B00h
F5E0h
E6F0h
C900h
FF80h
5000h
0080h
0000h
LSb
2
0
0
HYST
.
MSB
LSB
OS
is

Related parts for DS1775R1+T&R