DS1626S+T&R Maxim Integrated Products, DS1626S+T&R Datasheet - Page 8

IC THERMOMETER/STAT DIG 8-SOIC

DS1626S+T&R

Manufacturer Part Number
DS1626S+T&R
Description
IC THERMOMETER/STAT DIG 8-SOIC
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS1626S+T&R

Function
Thermometer, Thermostat
Topology
ADC (Sigma Delta), Comparator, Register Bank
Sensor Type
Internal
Sensing Temperature
-55°C ~ 125°C
Output Type
3-Wire Serial
Output Alarm
Yes
Output Fan
No
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (5.3mm Width), 8-SOP, 8-SOEIAJ
Full Temp Accuracy
+/- 2 C
Digital Output - Bus Interface
Serial (3-Wire)
Digital Output - Number Of Bits
12 bit
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
CPU BIT AND STAND-ALONE THERMOSTAT OPERATION
In stand-alone thermostat mode, DS1626/DS1726 thermostat functionality can be used without requiring
a microcontroller to start/stop temperature conversions. The CPU bit in the configuration register
determines if stand-alone mode is enabled.
When CPU = 1 stand-alone mode is disabled, and the only way to start/stop temperature conversions is
by using a microcontroller to transmit Start Convert T and Stop Convert T commands, respectively.
Stand-alone mode is enabled when CPU = 0. In this mode, when RST = 0 the CLK/CNV pin operates as
a control signal to start and stop temperature measurements. Driving CLK/CNV low initiates continuous
temperature conversions that will continue until CLK/CNV is brought high again. If the CLK/CNV pin is
driven low and then returned to a high state in less than 10ms, only one temperature conversion will be
performed after which the DS1626/DS1726 will return to a low-power idle state (i.e., one-shot operation).
Note that when stand-alone mode is enabled, the 1SHOT bit in the configuration register is ignored, and
only the CLK/CNV signal determines whether continuous or one-shot conversions take place.
Since T
stand-alone operation. If desired, the CLK/CNV and RST pin can be connected to GND so the
DS1626/DS1726 will automatically begin taking temperature measurements at power-up
Normal bus communication with the DS1626/DS1726 can still take place in stand-alone mode when
RST = 1. When communication is initiated, stand-alone conversions are automatically halted. If during
the bus communication continuous temperature conversions are started using the Start Convert T
command, they can only be stopped by issuing a Stop Convert T command.
Figure 5. THERMOSTAT OUTPUT OPERATION
H
, T
L
, and the CPU bit are stored in EEPROM, the DS1626/DS1726 can be preprogrammed for
T
T
T
COM
HIGH
LOW
LOGIC 0
LOGIC 0
LOGIC 0
LOGIC 1
LOGIC 1
LOGIC 1
T
L
8 of 12
T
H
TEMP
TEMP
TEMP
DS1626/DS1726

Related parts for DS1626S+T&R