ADT7462ACPZ-REEL7 ON Semiconductor, ADT7462ACPZ-REEL7 Datasheet - Page 61

no-image

ADT7462ACPZ-REEL7

Manufacturer Part Number
ADT7462ACPZ-REEL7
Description
IC TEMP/VOLT MONITOR 32-LFCSP
Manufacturer
ON Semiconductor
Datasheet

Specifications of ADT7462ACPZ-REEL7

Function
Fan Control, Temp Monitor
Topology
ADC, Comparator, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Type
SMBus™
Output Alarm
No
Output Fan
Yes
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
32-LFCSP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
1. POR = 0x00, Lock = Y, SW Reset = Y.
1. POR = 0x00, Lock = Y, SW Reset = Y.
1. POR = 0x0F, Lock = Y, SW Reset = Y.
Table 34. Register 0x03 — Configuration Register 3
Table 35. Register 0x07 — TACH Enable Register
Table 36. Register 0x08 — TACH Configuration Register
[7:4]
Bit
Bit
Bit
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
VID_Threshold
SDA_Timeout
SCL_Timeout
V_Core_Low
Threshold
XOR Tree
GPIO_En
Reserved
THERM_
CI Reset
TACH1
TACH2
TACH3
TACH4
TACH5
TACH6
TACH7
TACH8
DC 1/5
DC 2/6
DC 3/7
DC 4/8
Name
Name
Name
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
Setting this bit to 1 enables the GPIOs. Default = 0.
1 = SCL timeout enabled. 0 = SCL timeout disabled = default.
1 = SDA timeout enabled. 0 = SDA timeout disabled = default.
This bit sets the digital threshold for the VID digital inputs. 0 =default. 1 = low thresholds
selected = 0.65 V.
This bit sets the digital threshold for the THERM digital inputs. 0 =default. 1 = low thresholds
selected = 2/3 V
Setting this bit to 1 resets the chassis intrusion circuit. This bit clears itself. Default = 0.
Setting this bit to 1 enables the XOR tree test. Default = 0.
Setting this bit to 1 enables V_core_low. Default = 0.
Setting this bit to 1 enables the TACH1 measurement. Default = 0.
Setting this bit to 1 enables the TACH2 measurement. Default = 0.
Setting this bit to 1 enables the TACH3 measurement. Default = 0.
Setting this bit to 1 enables the TACH4 measurement. Default = 0.
Setting this bit to 1 enables the TACH5 measurement. Default = 0.
Setting this bit to 1 enables the TACH6 measurement. Default = 0.
Setting this bit to 1 enables the TACH7 measurement. Default = 0.
Setting this bit to 1 enables the TACH8 measurement. Default = 0.
Setting this bit to 1 enables continuous measurements on TACH1 and TACH5 in low frequency
PWM mode. Continuous measurement means that pulse stretching is turned off and the PWM
output and TACH inputs are no longer synchronized. Default = 1.
Setting this bit to 1 enables continuous measurements on TACH2 and TACH6 in low frequency
PWM mode. Continuous measurement means that pulse stretching is turned off and the PWM
output and TACH inputs are no longer synchronized. Default = 1.
Setting this bit to 1 enables continuous measurements on TACH3 and TACH7 in low frequency
PWM mode. Continuous measurement means that pulse stretching is turned off and the PWM
output and TACH inputs are no longer synchronized. Default = 1.
Setting this bit to 1 enables continuous measurements on TACH4 and TACH8 in low frequency
PWM mode. Continuous measurement means that pulse stretching is turned off and the PWM
output and TACH inputs are no longer synchronized. Default = 1.
Reserved for future use.
http://onsemi.com
CCP1
(Note 1)
(Note 1)
(Pin 23).
61
(Note 1)
Description
Description
Description

Related parts for ADT7462ACPZ-REEL7