MAX15031ATE+ Maxim Integrated Products, MAX15031ATE+ Datasheet - Page 9

IC BOOST CONV/CURRENT MON 16TQFN

MAX15031ATE+

Manufacturer Part Number
MAX15031ATE+
Description
IC BOOST CONV/CURRENT MON 16TQFN
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX15031ATE+

Applications
Converter Current Monitor, APD Bias Applications
Voltage - Input
2.7 ~ 11 V
Number Of Outputs
1
Voltage - Output
3.7 ~ 76 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-TQFN Exposed Pad
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
PIN
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
9
CLAMP
CNTRL
NAME
MOUT
SGND
SHDN
PGND
RLIM
PWR
BIAS
ILIM
APD
CP
CN
FB
EP
LX
IN
80V, 300mW Boost Converter and Current
_______________________________________________________________________________________
Boost Converter Input Voltage. PWR powers the switch driver and charge pump. Bypass PWR to PGND with a
ceramic capacitor of 1μF minimum value.
Positive Terminal of the Charge-Pump Flying Capacitor for 2.7V to 5.5V Supply Voltage Operation. Connect
CP to IN when the input voltage is in the 5.5V to 11V range.
Negative Terminal of the Charge-Pump Flying Capacitor for 2.7V to 5.5V Supply Voltage Operation. Leave CN
unconnected when the input voltage is in the 5.5V to 11V range.
Input Supply Voltage. IN powers all blocks of the MAX15031 except the switch driver and charge pump.
Bypass IN to PGND with a ceramic capacitor of 1μF minimum value.
Signal Ground. Connect directly to the local ground plane. Connect SGND to PGND at a single point, typically
near the return terminal of the output capacitor.
Feedback Regulation Input. Connect FB to the center tap of a resistive voltage-divider from the output (V
to SGND to set the output voltage. The FB voltage regulates to 1.245V (typ) when V
and to V
Control Input for Boost Converter Output-Voltage Programmability. Allows the feedback set-point voltage to be
set externally by CNTRL when V
1.245V (typ) feedback set-point voltage.
Open-Drain Current-Limit Indicator. ILIM asserts low when the APD current limit has been exceeded.
Current-Limit Resistor Connection. Connect a resistor from RLIM to SGND to program the APD current-limit
threshold.
Current-Monitor Output. MOUT sources a current 1/10th of I
Clamp Voltage Input. CLAMP is the external potential used for voltage clamping of MOUT.
Reference Current Output. APD provides the source current to the cathode of the photodiode.
Bias Voltage Input. Connect BIAS to the boost converter output (V
filter for ripple attenuation. BIAS provides the voltage bias for the current monitor and is the current source for
APD.
Active-Low Shutdown Control Input. Apply a logic-low voltage to SHDN to shut down the device and reduce
the supply current to 2μA (max). Connect SHDN to IN for normal operation. Ensure that V
than the input voltage, V
Power Ground. Connect the negative terminals of the input and output capacitors to PGND. Connect PGND
externally to SGND at a single point, typically at the return terminal of the output capacitor.
Drain of Internal 80V n-Channel DMOS. Connect inductor and diode to LX. Minimize the trace area at LX to
reduce switching noise emission.
Exposed Pad. Connect EP to a large contiguous copper plane at SGND potential to improve thermal
dissipation. Do not use as the main SGND connection.
CNTRL
voltage when V
Monitor for APD Bias Applications
IN
.
CNTRL
CNTRL
is below 1.245V (typ).
is less than 1.245V. Pull CNTRL above 1.5V (typ) to use the internal
FUNCTION
APD
.
OUT
) either directly or through a lowpass
Pin Description
CNTRL
SHDN
is above 1.5V (typ)
is not greater
OUT
)
9