TLE6368G2 Infineon Technologies, TLE6368G2 Datasheet - Page 15

no-image

TLE6368G2

Manufacturer Part Number
TLE6368G2
Description
IC PS SYSTEM MULTI VOLT DSO36
Manufacturer
Infineon Technologies
Datasheet

Specifications of TLE6368G2

Applications
Power Supply, Automotive Applications
Voltage - Input
5.5 ~ 60 V
Number Of Outputs
3
Voltage - Output
2.6V, 3.3V, 5V
Operating Temperature
-40°C ~ 150°C
Mounting Type
Surface Mount
Package / Case
DSO-36
Packages
PG-DSO-36
Comment
Vin up to 60V; 3 linear post regulators (5V, 3.3/2.6V, 5/3.3V) and 6 voltage trackers (5V); SPI
Vq (max)
5.0 V, 3.3/2.6 V, 3.3/2.6 V
Iq (max)
1,500.0 mA
Iq (typ)
30.0 µA
Output
Linear (Buck Preregulator)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TLE6368G2
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
TLE6368G2
0
Company:
Part Number:
TLE6368G2
Quantity:
4 800
Figure 6 Window watchdog timing definition
Figure 6 shows some guidelines for designing the watchdog trigger timing taking the
oscillator deviation of different devices into account. Of importance (w.c.) is the
maximum of the closed window and the minimum of the open window in which the trigger
has to occur.
The length of the OW and CW can be modified by SPI command. If a change of the
window length is desired during the Watchdog function is operating please send the SPI
command with the new timing with a “Watchdog trigger Bit” D15=1. In this case the next
CW will directly start with the new length.
A minimum time gap of > 1/48 of the actual OW/CW time between a “Watchdog disable”
and ’Watchdog enable’ SPI-command should be maintained. This allows the internal
Watchdog counters to be resetted. Thus after the enable command the Watchdog will
start properly with a full CW of the adjusted length.
Data Sheet
worst cases
definition
definition
f
f
OSC
OSC
=f
=f
OSCmax
OSCmin
Minimum open window time:
t
t
EOW, w.c.
closed window
ECW, w.c.
t
CW
=t
= ( t
= t
CW
CW
CW
(1+ )
+t
t
ECW
OW
)(1- )
open window
t
OWmin
t
OW
=t
CW
t
t
OWmin
EOW
reset start delay time after window
= end of open window
= t
reset delay time without trigger
OW
(not the same scale)
-
watchdog timeout
15
* ( t
t
SR
OW
= t
OW
+ 2* t
/2
CW
)
Example with:
t
t
t
t
CW
ECW, w.c.
EOW, w.c
owmin
=25% (oscillator deviation)
=128ms
reset duration time after window
(not the same scale)
= 128(1.25) = 160ms
Rev. 2.3, 2009-05-04
= 32ms
= (128+128)(0.75) = 192ms
watchdog time-out
t
WDR
= t
TLE6368-G2
RES