L6711 STMicroelectronics, L6711 Datasheet - Page 46

IC CTRLR 3PHASE VID/DACS 48-TQFP

L6711

Manufacturer Part Number
L6711
Description
IC CTRLR 3PHASE VID/DACS 48-TQFP
Manufacturer
STMicroelectronics
Type
Step-Down (Buck)r
Datasheet

Specifications of L6711

Internal Switch(s)
No
Synchronous Rectifier
No
Number Of Outputs
1
Voltage - Output
0.8 ~ 1.55 V
Current - Output
2A
Frequency - Switching
150kHz
Voltage - Input
12V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
48-TQFP Exposed Pad, 48-eTQFP, 48-HTQFP, 48-VQFP
Power - Output
2.5W
Output Voltage
0.8 V to 1.581 V
Output Current
95 A
Input Voltage
13.8 V
Mounting Style
SMD/SMT
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
0 C
Case
QFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
L6711
Manufacturer:
STMicroelectronics
Quantity:
10 000
Part Number:
L6711
Manufacturer:
ST
0
Part Number:
L6711
Manufacturer:
ST
Quantity:
20 000
Part Number:
L6711 @@@@@@@@@@
Manufacturer:
ST
0
Part Number:
L6711DBS
Manufacturer:
ST
0
Part Number:
L6711TR
Manufacturer:
STMicroelectronics
Quantity:
10 000
Layout guidelines
18.3
46/50
Current sense connections.
Remote Buffer: The input connections for this component must be routed as parallel nets
from the FBG/FBR pins to the load in order to compensate losses along the output power
traces and also to avoid the pick-up of any common mode noise. Connecting these pins in
points far from the load will cause a non-optimum load regulation, increasing output
tolerance.
Current Reading: The Rg resistors have to be placed as close as possible to the CSx- and
CSx+ pins in order to limit the noise injection into the device; this is still valid also for the
R
connecting these resistors to the reading point must use dedicated nets, routed as parallel
traces in order to avoid the pick-up of any common mode noise.
Figure 24. Device orientation (left) and sense nets routing (right: red for Lsense,
It's also important to avoid any offset in the measurement and, to get a better precision, to
connect the traces as close as possible to the sensing elements. Symmetrical layout is also
suggested.
Small filtering capacitor can be needed between VOUT and SGND on the CSx- line, placed
near the controller, allowing higher layout flexibility in the current sense connection.
g(RC)
-Cg network used when sensing current across the inductor. The PCB traces
black for LSsense)
VCCDR
R
R
R
R
R
C
R
R
C
L6711

Related parts for L6711