HCPL-7601#300 Avago Technologies US Inc., HCPL-7601#300 Datasheet - Page 7

OPTOCOUPLER 10MBD 8-SMD GW

HCPL-7601#300

Manufacturer Part Number
HCPL-7601#300
Description
OPTOCOUPLER 10MBD 8-SMD GW
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HCPL-7601#300

Package / Case
8-SMD Gull Wing
Voltage - Isolation
3750Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
50mA
Data Rate
10MBd
Propagation Delay High - Low @ If
57ns @ 4mA
Current - Dc Forward (if)
20mA
Input Type
DC
Output Type
Open Collector
Mounting Type
Surface Mount, Gull Wing
Isolation Voltage
3750 Vrms
Maximum Continuous Output Current
50 mA
Maximum Fall Time
10 ns
Maximum Forward Diode Current
20 mA
Maximum Rise Time
24 ns
Minimum Forward Diode Voltage
1.2 V
Output Device
Logic Gate Photo IC
Configuration
1 Channel
Maximum Baud Rate
10 MBps
Maximum Forward Diode Voltage
1.85 V
Maximum Reverse Diode Voltage
3 V
Maximum Power Dissipation
250 mW
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
HCPL-7601#300HCPL-7601
Manufacturer:
AGILENT
Quantity:
28
Company:
Part Number:
HCPL-7601#300HCPL-7601
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Company:
Part Number:
HCPL-7601#300HCPL-7601-000E
Manufacturer:
AVAGO
Quantity:
10 000
Company:
Part Number:
HCPL-7601#300HCPL-7601-000E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Company:
Part Number:
HCPL-7601#300HCPL-7601-300E
Manufacturer:
AVAGO
Quantity:
10 000
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics
* This part may also be used in Pollution Degree 3 environments where the rated mains voltage is 300 V
** Refer to the front of the optocoupler section of the current Optoelectronics Designers Catalog for a more detailed description of IEC/EN/DIN EN
Insulation Related Specifications
7
60747-5-2 and other product safety regulations.
Description
Installation classification per DIN VDE 0109*/12.83, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0109/12.83)*
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b** V
Production test with t
Partial discharge < 5 pC
Input to Output Test Voltage, Method a** V
Production test with t
Partial discharge < 5 pC
Highest Allowable Overvoltage**
(Transient Overvoltage, t
Safety-limiting values (Maximum values allowed in the event
of a failure, also see Figure 16)
Insulation Resistance at T
Parameter
Minimum External Clearance
(External Air Gap)
Minimum External Creepage
(External Tracking)
Minimum Internal Clearance
(Internal Plastic Gap)
Comparative Tracking Index
Isolation Group (per DIN VDE 0109)
for rated mains voltage 300 V
for rated mains voltage 600 V
Case Temperature
Input Power
Output Power
P
P
= 1 sec,
= 60 sec,
TR
SI
= 10 sec)
, V
IO
= 500 V
RMS
RMS
V
R
IORM
PR
IS
PR
= 1.2 X V
= 1.6 X V
Symbol
L (IO1)
L (IO2)
CTI
IORM
IORM
Value
175
IIIa
7.0
8.0
0.5
Units
mm
mm
mm
V
P
Symbol
P
SI,Output
SI,Input
600
V
V
V
T
10
2
PR
PR
TR
SI
Conditions
Measured from input terminals
to output terminals
Measured from input terminals
to output terminals
Through insulation distance
from conductor to conductor
DIN IEC 112/VDE 303 P1
Material Group
11
RMS
(per DIN VDE 0190/12.83).
Characteristics
40/85/21
V
1357
1018
6000
I-IV
I-III
848
960
720
175
250
RMS
80
V
V
Unit
V
V
V
V
mW
mW
peak
RMS
peak
RMS
peak
peak
C