ACPL-312U-300E Avago Technologies US Inc., ACPL-312U-300E Datasheet - Page 4

OPTOCOUPLER IGBT 2.5A 8-SMD GW

ACPL-312U-300E

Manufacturer Part Number
ACPL-312U-300E
Description
OPTOCOUPLER IGBT 2.5A 8-SMD GW
Manufacturer
Avago Technologies US Inc.
Series
R²Coupler™r
Datasheet

Specifications of ACPL-312U-300E

Voltage - Isolation
3750Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
2.5A
Propagation Delay High - Low @ If
300ns @ 7mA ~ 16mA
Current - Dc Forward (if)
20mA
Input Type
DC
Output Type
Push-Pull, Totem-Pole
Mounting Type
Surface Mount
Package / Case
8-SMD Gull Wing
No. Of Channels
1
Optocoupler Output Type
Gate Drive
Input Current
16mA
Output Voltage
30V
Opto Case Style
SMD
No. Of Pins
8
Output Current
500mA
Output Voltage Max
27V
Isolation Voltage
3.75kV
Forward Current If
20mA
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Insulation and Safety Related Specifications
All Avago data sheets report the creepage and clearance
inherent to the optocoupler component itself. These di-
mensions are needed as a starting point for the equipment
designer when determining the circuit insulation require-
ments. However, once mounted on a printed circuit board,
minimum creepage and clearance requirements must be
met as specified for individual equipment standards. For
creepage, the shortest distance path along the surface
IEC/EN/DIN EN 60747-5-5 Insulation Related Characteristics
Notes:
1. Insulation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits within the
4
Parameter
Minimum External Air Gap
(Clearance)
Minimum External Tracking
(Creepage)
Minimum Internal Plastic Gap
(Internal Clearance)
Tracking Resistance
(Comparative Tracking Index)
Isolation Group
(DIN VDE0109)
Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b
V
Test t
Input to Output Test Voltage, Method a
V
t
Highest Allowable Overvoltage
(Transient Overvoltage, t
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Thermal Derating curve, Figure 11.)
Insulation Resistance at T
m
IORM
IORM
for rated mains voltage ≤150 V rms
for rated mains voltage ≤300 V rms
for rated mains voltage ≤450 V rms
for rated mains voltage ≤600 V rms
for rated mains voltage ≤1000 V rms
application.
= 60 sec, Partial Discharge < 5 pC
Case Temperature
Input Current
Output Power
m
x 1.875 = V
x 1.5 = V
= 1 sec, Partial Discharge < 5 pC
PR
, 100% Type and Sample Test
PR
, 100% Production
ini
S
, V
= 10 sec)
10
= 500 V
Symbol
L(101)
L(102)
CTI
Value
7.1
7.4
0.08
>175
IIIa
Units
mm
mm
mm
Volts
[1]
Conditions
Measured from input terminals to output terminals, shortest
distance through air.
Measured from input terminals to output terminals, shortest
distance path along body.
Through insulation distance conductor to conductor, usually the
straight line distance thickness between the emitter and detector.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110)
of a printed circuit board between the solder fillets of
the input and output leads must be considered. There
are recommended techniques such as grooves and ribs
which may be used on a printed circuit board to achieve
desired creepage and clearances. Creepage and clearance
distances will also change depending on factors such as
pollution degree and insulation level.
Symbol
V
V
V
V
T
I
Ps
R
s, INPUT
s
IORM
PR
PR
IOTM
IO
,OUTPUT
ACPL-312U
I-IV
I-IV
I-III
55/125/21
2
630
1181
945
6000
175
230
600
≥10
9
Units
V
V
V
V
°C
mA
mW
:
PEAK
PEAK
PEAK
PEAK

Related parts for ACPL-312U-300E