ACPL-312U-300E Avago Technologies US Inc., ACPL-312U-300E Datasheet - Page 7

OPTOCOUPLER IGBT 2.5A 8-SMD GW

ACPL-312U-300E

Manufacturer Part Number
ACPL-312U-300E
Description
OPTOCOUPLER IGBT 2.5A 8-SMD GW
Manufacturer
Avago Technologies US Inc.
Series
R²Coupler™r
Datasheet

Specifications of ACPL-312U-300E

Voltage - Isolation
3750Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
2.5A
Propagation Delay High - Low @ If
300ns @ 7mA ~ 16mA
Current - Dc Forward (if)
20mA
Input Type
DC
Output Type
Push-Pull, Totem-Pole
Mounting Type
Surface Mount
Package / Case
8-SMD Gull Wing
No. Of Channels
1
Optocoupler Output Type
Gate Drive
Input Current
16mA
Output Voltage
30V
Opto Case Style
SMD
No. Of Pins
8
Output Current
500mA
Output Voltage Max
27V
Isolation Voltage
3.75kV
Forward Current If
20mA
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Package Characteristics
*
** The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous voltage
Notes:
1. Derate linearly above 70°C free-air temperature at a rate of 0.0727 mA/°C.
2. Maximum pulse width = 10 Ps, maximum duty cycle = 0.2%. This value is intended to allow for component tolerances for designs with IO peak
3. Derate linearly above 70°C free-air temperature at a rate of 5.0 mW/°C.
4. Derate linearly above 70°C free-air temperature at a rate of 5.0 mW/°C. The maximum LED junction temperature should not exceed 150°C.
5. Maximum pulse width = 50 Ps, maximum duty cycle = 0.5%.
6. In this test V
7. Maximum pulse width = 1 ms, maximum duty cycle = 20%.
8. In accordance with UL1577, each optocoupler is proof tested by applying an insulation test voltage ≥4500 Vrms for 1 second (leakage detection
9. Device considered a two-terminal device: pins 1, 2, 3, and 4 shorted together and pins 5, 6, 7, and 8 shorted together.
10. The difference between t
11. Pins 1 and 4 need to be connected to LED common.
12. Common mode transient immunity in the high state is the maximum tolerable dV
13. Common mode transient immunity in a low state is the maximum tolerable dV
14. This load condition approximates the gate load of a 1200 V/75A IGBT.
15. Pulse Width Distortion (PWD) is defined as |t
7
Parameter
Input-Output Momentary
Withstand Voltage**
Resistance (Input-Output)
Capacitance (Input-Output)
LED-to-Case Thermal
Resistance
LED-to-Detector Thermal
Resistance
Detector-to-Case Thermal
Resistance
All typicals at T
rating. For the continuous voltage rating refers to your equipment level safety specification or Avago Application Note 1074 entitled “Optocoupler
Input-Output Endurance Voltage. ”
minimum = 2.0 A. See Applications section for additional details on limiting I
current limit, II-O ≤ 5 PA).
will remain in the high state (i.e., V
will remain in a low state (i.e., V
OH
A
is measured with a dc load current. When driving capacitive loads V
= 25°C.
PHL
and t
O
< 1.0 V).
Symbol
V
R
C
T
T
T
PLH
O
LC
LD
DC
ISO
I-O
I-O
> 15.0 V).
between any two ACPL-312U parts under the same test condition.
PHL
-t
Min.
3750
PLH
| for any given device.
Typ.*
10
0.8
467
442
126
12
Max.
OH
Units
V
:
pF
°C/W
°C/W
°C/W
CM
peak.
RMS
CM
/dt of the common mode pulse, V
OH
/dt of the common mode pulse, V
will approach V
Test Conditions
RH < 50%, t = 1 min.
T
V
ƒ = 1 MHz
Thermocouple located at
center underside of package
A
I-O
= 25°C
= 500 V
CC
DC
as I
OH
approaches zero amps.
CM
CM
, to assure that the output
, to assure that the output
Fig.
28
Note
8, 9
9

Related parts for ACPL-312U-300E