M0216SD-162SDAR2-1 Newhaven Display, M0216SD-162SDAR2-1 Datasheet - Page 23

MODULE VF CHAR 2X16 5.34MM

M0216SD-162SDAR2-1

Manufacturer Part Number
M0216SD-162SDAR2-1
Description
MODULE VF CHAR 2X16 5.34MM
Manufacturer
Newhaven Display
Datasheet

Specifications of M0216SD-162SDAR2-1

Outline L X W X H
80.00mm x 36.00mm x 18.00mm
Viewing Area
51.80mm L x 11.50mm W
Display Format
16 x 2
Display Type
Character
Format
5 x 8 Dots
Voltage - Supply
5V
Character Size
5.34mm H x 2.10mm W
Operating Temperature
-40°C ~ 85°C
Product
Character Display Modules
Character Count X Line
16 x 2
Module Size (w X H X T)
80 mm x 36 mm x 18 mm
Voltage Rating
5 V
Operating Temperature Range
- 40 C to + 85 C
Dot Format
5 x 8
Viewing Area (w X H)
51.8 mm x 11.5 mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Interface
-
Number Of Dots
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
STANDARD
NAME
6.6 RESET CONDITIONS
After either a power-up reset or an external reset, the modules initialize to the following conditions:
1) All DDRAM locations are set to 20H (character code for a space).
2) The AC is set to DDRAM address 00H (i.e. sets cursor position to 00H).
3) The relationship between DDRAM addresses and character positions on the VFD is set to the non-
4) Entry Mode Set instruction bits:
5) Display On/Off Control instruction bits:
6) Function Set instruction bits:
Note that the function set command must be the first instruction sent to the module after any reset.
6.6.1 INITIALIZATION
The modules can be initialized by using instructions if the modules are not reset according to the reset
timing detailed in Section 3.7.1 (Reset Timing). After any reset, the function set command must be the
first instruction sent to the module.
shifted position.
I/D = 1:
S = 0:
D = 0:
C = 0:
B = 0:
DL = 1:
N = 1(0): Number of display lines set to 2 for multiple line displays (number of display lines
BR1,BR0 = 0,0:
The AC increments after each DDRAM or CGRAM access.
The display shift function is disabled.
The display is off (display blank).
The cursor is off.
The blinking character function is disabled.
Sets the data bus width for the parallel interface modes to 8-bit (DB7-DB0).
set to 1 for single line displays).
Sets the luminance level to 100%.
M0216SD-162SDAR2-1
DOCUMENT NO.
REV. NO.
03
PAGE
23/24

Related parts for M0216SD-162SDAR2-1