HLMP-HL31-RU000 Avago Technologies US Inc., HLMP-HL31-RU000 Datasheet
HLMP-HL31-RU000
Specifications of HLMP-HL31-RU000
Available stocks
Related parts for HLMP-HL31-RU000
HLMP-HL31-RU000 Summary of contents
Page 1
Mini Oval Mid Power AlInGaP LEDs Data Sheet Description These Precision Optical Performance Oval LEDs are specially designed for full color/video and passenger information signs. The oval shaped radiation pattern and high luminous intensity ensure that these devices ...
Page 2
... HLMP-AD30-UX000 No HLMP-AD31-UX000 Yes HLMP-AL30-TW000 No HLMP-AL31-TW000 Yes Notes: 1. The luminous Intensity is measured on the axis of the lamps packages. 2. The optical axis is closely aligned with the package mechanical axis. 3. The dominant wavelength, λ is derive from the CIE Chromaticity Diagram and represents the color of the lamps. ...
Page 3
... Part Numbering System HLMP – Absolute Maximum Rating (TA = 25° ° ° ° ° C) Parameters Value DC forward current [ Peak pulsed forward current 100 mA Average forward current 70 mA Reverse voltage (Ir = 100 LED junction temperature 130 C Operating temperature - +100 C Storage temperature - +120 C Wave soldering temperature ...
Page 4
Electrical and Optical Characteristics at TA=25°C Parameters Min Forward voltage Amber (λd=592 nm) Red (λd=626 nm) Reverse voltage 5 Peak Wavelength: Amber (λd=592 nm) Red (λd=626 nm) Spectral Halfwidth Amber (λd=592 nm) Red (λd=626 nm) Capacitance Amber (λd=592 nm) Red ...
Page 5
RELATIVE LUMINOUS INTENSITY VS WAVELENGTH 1.0 0.8 Amber 0.6 0.4 0.2 0.0 380 480 580 WAVELENGTH - nm Figure 1. Relative Intensity vs. Wavelength 1.2 1.0 0.8 Red 0.6 0.4 0 ...
Page 6
Intensity Bin Limits (mcd at 70 mA) Bin Name Min. Max. S 1900 2500 T 2500 3200 U 3200 4200 V 4200 5500 W 5500 7200 X 7200 9300 Tolerance for each bin limits is ±15% For product information and ...