HHS60ZB-NT POWER ONE, HHS60ZB-NT Datasheet

CONV DC-DC 48V IN 1.8V OUT 108W

HHS60ZB-NT

Manufacturer Part Number
HHS60ZB-NT
Description
CONV DC-DC 48V IN 1.8V OUT 108W
Manufacturer
POWER ONE
Series
HHSr
Type
Isolatedr
Datasheet

Specifications of HHS60ZB-NT

Output
1.8V
Number Of Outputs
1
Power (watts)
108W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module, 1/2 Brick
1st Output
1.8 VDC @ 60A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
108W
Operating Temperature
-40°C ~ 110°C
Efficiency
86%
Approvals
CSA, cUL, TUV, UL
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
179-2243

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HHS60ZB-NT
Manufacturer:
RECOM
Quantity:
500
Part Number:
HHS60ZB-NT
Manufacturer:
POWER
Quantity:
20 000
Applications
• Distributed power architectures
• Telecommunications equipment
• LAN/WAN
• Data processing
Description
The HHS60 Series of high-density, single-output dc-dc converters is ideal for telecom and datacom systems that
require low voltage at high current in an industry-standard, half-brick footprint. Highly efficient topology and
thermally-optimized construction allow the units to provide high output current in the system over a wide operating
temperature range while still maintaining a safe guardband for component electrical and thermal ratings. The
addition of an external heat sink increases the capacity of the unit. The HHS60 employs 100% surface-mount
components for consistency and reliability in our production process, and is available in four standard output
voltages from 1.5 to 3.3 VDC.
JUN 06, 2006 revised to JUL 25, 2006
NOTES:
1
should be followed.
Model Selection
This product is intended for integration into end-use equipment. All the required procedures for CE marking of end-use equipment
specified @ V
HHS60ZE
HHS60ZD
HHS60ZB
HHS60ZA
Model
IN
Model numbers highlighted in yellow or shaded are not recommended for new designs.
min.
Voltage
36-75
36-75
36-75
36-75
Input
VDC
Max
Current,
Input
6.5
4.9
3.6
3.1
1
ADC
48VDC Input, 60 Amp Half-Brick Converter
Voltage
Output
Page 1 of 12
VDC
3.3
2.5
1.8
1.5
Output Rated
Current I
Features
HHS60 DC-DC Series Data Sheet
ADC
RoHS lead solder exemption compliant
Standard ½-brick footprint and pinout
100V/100ms input voltage surge
Low profile (12.7 mm)
Input-to-output isolation: 1500 VDC
Basic insulation
High efficiency - to 90% at full load
Start-up into high capacitive load
Start-up into pre-biased loads
Back-drive protection
Remote sense
Low conducted and radiated EMI
Output overcurrent & overvoltage protection
Overtemperature protection
Remote On/Off (primary referenced), positive
or negative logic
Output voltage trim adjust, positive or
negative
UL 1950 recognized, CSA 22.2 No. 950-95
certification, TUV IEC95
60
60
60
60
rated
Ripple/Noise,
mV p-p
Output
150
150
150
150
www.power-one.com
Efficiency @
Typical
I
rated
90
89
86
85
%

Related parts for HHS60ZB-NT

HHS60ZB-NT Summary of contents

Page 1

... Input Voltage VDC HHS60ZE 36-75 HHS60ZD 36-75 HHS60ZB 36-75 HHS60ZA 36-75 This product is intended for integration into end-use equipment. All the required procedures for CE marking of end-use equipment should be followed. Model numbers highlighted in yellow or shaded are not recommended for new designs. NOTES: ...

Page 2

Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely effect long- term reliability, and cause permanent damage to the converter. Parameter Input voltage Operating Temperature Storage Temperature ON/OFF Control Voltage 1 O Max. ...

Page 3

Input Specifications All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Parameter Input Voltage Turn-On Input Voltage Turn-Off Input Voltage Input Reflected Ripple Current Inrush Transient 1 Refer to Fig. 9 for waveform. 2 ...

Page 4

Protections Specifications All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Parameter Type Threshold Short Circuit Type Threshold Type Threshold Recovery 1 2 See Fig. 13 See Fig. 14 Feature Specifications All specifications apply ...

Page 5

... Figure 1. HHS60ZE, (3.3V) Efficiency Curves 36V Output current, A Figure 2. HHS60ZD (2.5V) Efficiency Curves 36V Output current, A Figure 3. HHS60ZB (1.8V) Efficiency Curves JUN 06, 2006 revised to JUL 25, 2006 HHS60 DC-DC Series Data Sheet 48VDC Input, 60 Amp Half-Brick Converter 48V 75V 48V 75V 48V 75V Page 36V 48V ...

Page 6

... ( LFM) 0 Data Rev Figure 8. HHS60ZA (1.5V) Derating Curves 70 85 Page THERMAL DERATING CURVE HHS60ZB Vin = 54V, Orientation : Vin- to Vin + 100 LFM 200 LFM 300 LFM 400 LFM Ambient Temperature (Deg C) THERMAL DERATING CURVE HHS60ZA Vin = 54V, Orientation : Vin- to Vin + 100 LFM ...

Page 7

UVLO Operation Input Current vs. Voltage 7 6.5 6 5.5 5 4.5 4 Turn On Voltage 3.5 Threshold 3 2.5 Turn Off Voltage Threshold 2 1 Input Voltage (Vdc) Figure 9. HHS60 ...

Page 8

Short Circuit Operation Figure 13. Output Current with Shorted Output Pins, Vin = 48Vdc, Scale is 20Amp/Div. Once the output current is brought back into its specified range, the converter automatically exits the hiccup mode and continues normal operation. Overvoltage ...

Page 9

... Vo*(100-Δ%)-122.5 R trim-dn = R1*(--------------------------- ) - R2 kΩ The 122.5*R1 R trim-up = (------------- - R2) kΩ Where R1 and R2 are constants from the table below Model HHS60ZA HHS60ZB HHS60ZD HHS60ZE Page Vo*Δ% Vo*Δ% R1 (kΩ) R2 (kΩ) 0. 223 0.15 0.474 1 1.039 3 ...

Page 10

Optional Positive-Trim (–T, P/N suffix) The trim feature allows the user to adjust the output voltage from its nominal value. The HHS60 positive-trim (-T) models trim up with a resistor from the Trim (#7) pin to the +Sense (#8) pin ...

Page 11

The entire system, including the HHS60 converter, must pass withstand test for Reinforced insulation. Design of this type of systems engineering and under-standing of the overall safety requirements and should be performed by qualified personnel. Thermal Considerations The HHS60 ...

Page 12

Mechanical Drawing Tolerances: .xx + .020 (.5) .xxx + .010 (.25) Pin Diameter + 0.002 (.05) Ordering Information Options Remote ON/OFF Trim Pin Length Special Models Notes NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use ...