HHS60ZB-NT POWER ONE, HHS60ZB-NT Datasheet - Page 10

CONV DC-DC 48V IN 1.8V OUT 108W

HHS60ZB-NT

Manufacturer Part Number
HHS60ZB-NT
Description
CONV DC-DC 48V IN 1.8V OUT 108W
Manufacturer
POWER ONE
Series
HHSr
Type
Isolatedr
Datasheet

Specifications of HHS60ZB-NT

Output
1.8V
Number Of Outputs
1
Power (watts)
108W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module, 1/2 Brick
1st Output
1.8 VDC @ 60A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
108W
Operating Temperature
-40°C ~ 110°C
Efficiency
86%
Approvals
CSA, cUL, TUV, UL
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
179-2243

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HHS60ZB-NT
Manufacturer:
RECOM
Quantity:
500
Part Number:
HHS60ZB-NT
Manufacturer:
POWER
Quantity:
20 000
Optional Positive-Trim (–T, P/N suffix)
The trim feature allows the user to adjust the output
voltage from its nominal value.
The HHS60 positive-trim (-T) models trim up with a
resistor from the Trim (#7) pin to the +Sense (#8) pin
and trims down with a resistor from the Trim pin to
the –Sense (#6) pin as shown in the Figure 17.
The equations below determine the trim resistor
value required to achieve a ΔV change in the output
voltage.
where ΔV% is the output voltage change expressed
in percent of the nominal output voltage, Vout.
Notes:
1.
2.
3.
JUN 06, 2006 revised to JUL 25, 2006
R
When the output voltage is trimmed up, the output power
from the converter must not exceed its maximum rating. The
power is determined by measuring the output voltage on the
output pins, and multiplying it by the output current.
In order to avoid creating apparent load regulation
degradation, it is important that the trim resistors are
connected directly to the remote sense pins, and not to the
load or to traces going to the load.
The output voltage increase can be accomplished by either
the trim or by the remote sense or by the combination of
both.
trim-up = (-------------------- - ------------------) kΩ
Figure 17. HHS60 Series Positive Trim Schematic
In any case the absolute maximum output voltage
R
Vo*(100+Δ%)
trim-dn = (-------- - 2) kΩ
1.225*Δ%
100
Δ%
(100+2*Δ%)
Δ%
48VDC Input, 60 Amp Half-Brick Converter
Page 10 of 12
4.
Safety Considerations
The HHS60 Series converters feature 1500 VDC
isolation from input to output. The input to output
resistance is greater than 10MΩ. These converters
are provided with Basic insulation between input and
output circuits according to all IEC60950 based
standards.
converter needs to receive safety agency approval,
certain rules must be followed in the design of the
system.
clearance requirements of the end-use safety
requirements must be observed. These documents
include UL60950 - CSA60950-00 and EN60950,
although other or additional requirements may be
needed for specific applications.
The HHS60 Series converters have no internal fuse.
An external fuse must be provided to protect the
system from catastrophic failure, as illustrated in
figure 15. Refer to the “Input Fuse Selection for
DC/DC converters” application note on www.power-
one.com for proper selection of the input fuse. Both
input traces and the chassis ground trace (if
applicable) must be capable of conducting a current
of 1.5 times the value of the fuse without opening.
The fuse must not be placed in the grounded input
line, if any.
In order for the output of the HHS60 Series converter
to be considered as SELV (Safety Extra Low
Voltage) or TNV-1, according to all IEC60950 based
standards, one of the following requirements must be
met in the system design:
HHS60 DC-DC Series Data Sheet
increase shall not exceed the limits defined within the
“Features” section above.
Either Rup or Rdown should be used to adjust the output
voltage according to the equations above. If both Rup and
Rdown are used simultaneously, they will form a resistive
divider and the equations above will not apply
If the voltage source feeding the module is SELV
or TNV-2, the output of the converter may be
grounded or ungrounded.
If the voltage source feeding the module is ELV,
the output of the converter may be considered
SELV only if the output is grounded per the
requirements of the standard.
If the voltage source feeding the module is a
Hazardous Voltage
voltage source feeding the module must be
provided with at least Basic insulation between
the source to the converter and any hazardous
In particular, all of the creepage and
Nevertheless, if the system using the
Secondary
www.power-one.com
Circuit,
the

Related parts for HHS60ZB-NT