FW300A1 Lineage Power, FW300A1 Datasheet - Page 8

no-image

FW300A1

Manufacturer Part Number
FW300A1
Description
CONVERTER DC/DC 5V 300W OUT
Manufacturer
Lineage Power
Series
FW300r
Type
Isolated with Remote On/Offr
Datasheet

Specifications of FW300A1

Output
5V
Number Of Outputs
1
Power (watts)
300W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
Module
1st Output
5 VDC @ 60A
Size / Dimension
4.60" L x 2.40" W x 0.53" H (116.8mm x 61mm x 13.5mm)
Power (watts) - Rated
300W
Operating Temperature
-40°C ~ 100°C
Efficiency
84%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FW300A1
Manufacturer:
LUCENT
Quantity:
27
Part Number:
FW300A1
Quantity:
5 510
Part Number:
FW300A1
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
FW300A1
Quantity:
55
Part Number:
FW300A1 300W
Manufacturer:
IMP
Quantity:
100
Part Number:
FW300A1-33T
Manufacturer:
LUCENT
Quantity:
27
dc-dc Converters; 36 to 75 Vdc Input, 5 Vdc Output; 250 W to 300 W
FW250A1 and FW300A1 Power Modules:
Characteristic Curves
Note: Tested with a 10 µF aluminum and a 1.0 µF ceramic capacitor
Figure 9. Typical FW250A1 Transient Response to
Note: Tested with a 10 µF aluminum and a 1.0 µF ceramic capacitor
Figure 10. Typical FW250A1 Transient Response to
8 8
across the load.
across the load.
12.5
25.0
5
5
Step Decrease in Load from 50% to 25%
of Full Load at Room Temperature and
48 V Input (Waveform Averaged to
Eliminate Ripple Component.)
Step Increase in Load from 50% to 75%
of Full Load at Room Temperature and
48 V Input (Waveform Averaged to
Eliminate Ripple Component.)
TIME, t (200 µs/div)
TIME, t (200 µs/div)
(continued)
8-1753 (C)
8-1755 (C)
Note: Tested with a 10 µF aluminum and a 1.0 µF ceramic capacitor
Figure 11. Typical FW300A1 Transient Response to
Note: Tested with a 10 µF aluminum and a 1.0 µF ceramic capacitor
Figure 12. Typical FW300A1 Transient Response to
across the load.
across the load.
30
15
5
45
30
5
Step Decrease in Load from 50% to 25%
of Full Load at Room Temperature and
48 V Input (Waveform Averaged to
Eliminate Ripple Component.)
Step Increase in Load from 50% to 75%
of Full Load at Room Temperature and
48 V Input (Waveform Averaged to
Eliminate Ripple Component.)
TIME, t (200 µs/div)
TIME, t (200 µs/div)
Data Sheet
April 2008
Lineage Power
8-1754 (C)
8-1756 (C)

Related parts for FW300A1