FW300C1 Lineage Power, FW300C1 Datasheet

no-image

FW300C1

Manufacturer Part Number
FW300C1
Description
CONVERTER DC/DC 15V 300W OUT
Manufacturer
Lineage Power
Series
FW300r
Type
Isolated with Remote On/Offr
Datasheet

Specifications of FW300C1

Output
15V
Number Of Outputs
1
Power (watts)
300W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
Module
1st Output
15 VDC @ 20A
Size / Dimension
4.60" L x 2.40" W x 0.53" H (116.8mm x 61mm x 13.5mm)
Power (watts) - Rated
300W
Operating Temperature
-40°C ~ 100°C
Efficiency
87%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FW300C1
Manufacturer:
IR
Quantity:
1 000
Part Number:
FW300C1
Quantity:
55
Data Sheet
April 2008
Description
The FW250C1 and FW300C1 Power Modules are dc-dc converters that operate over an input voltage range of
36 Vdc to 75 Vdc and provide a precisely regulated dc output. The outputs are fully isolated from the inputs,
allowing versatile polarity configurations and grounding connections. The modules have maximum power rat-
ings from 250 W to 300 W at a typical full-load efficiency of 87%.
Two or more modules may be paralleled with forced load sharing for redundant or enhanced power applications.
The package, which mounts on a printed-circuit board, accommodates a heat sink for high-temperature
applications.
* ISO is a registered trademark of the International Organization for Standardization.
† UL is a registered trademark of Underwriters Laboratories, Inc.
‡ CSA is a registered trademark of Canadian Standards Assn.
§ VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
** This product is intended for integration into end-use equipment. All the required procedures for CE marking of end-use equipment should
dc-dc Converters; 36 to 75 Vdc Input, 15 Vdc Output; 250 W to 300 W
The FW250C1 and FW300C1 Power Modules use advanced,
surface-mount technology and deliver high-quality, compact,
dc-dc conversion at an economical price.
Applications
n
n
n
Options
n
be followed. (The CE mark is placed on selected products.)
Redundant and distributed power architectures
Computer equipment
Communications equipment
Heat sink available for extended operation
FW250C1 and FW300C1 Power Modules:
Features
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
Size: 61.0 mm x 116.8 mm x 13.5 mm
(2.40 in. x 4.60 in. x 0.53 in.)
Wide input voltage range
High efficiency: 87% typical
Parallel operation with load sharing
Output voltage set-point adjustment (trim)
Thermal protection
Synchronization
Power good signal
Current monitor
Output overvoltage and overcurrent protection
Constant frequency
Case ground pin
Input-to-output isolation
Remote sense
Remote on/off
Short-circuit protection
ISO* 9001 Certified manufacturing facilities
UL
Certified, and VDE
Licensed
CE mark meets 73/23/EEC and 93/68/EEC direc-
tives**
1950 Recognized, CSA
§
0805 (EN60950, IEC950)
C22.2 No. 950-95

Related parts for FW300C1

FW300C1 Summary of contents

Page 1

... Description The FW250C1 and FW300C1 Power Modules are dc-dc converters that operate over an input voltage range of 36 Vdc to 75 Vdc and provide a precisely regulated dc output. The outputs are fully isolated from the inputs, allowing versatile polarity configurations and grounding connections. The modules have maximum power rat- ings from 250 W to 300 typical full-load efficiency of 87% ...

Page 2

... Table 1. Input Specifications Parameter Operating Input Voltage Maximum Input Current ( V): I FW250C1 FW300C1 Inrush Transient Input Reflected-ripple Current, Peak-to-peak ( MHz, 12 µH source impedance; see Figure 8.) Input Ripple Rejection (120 Hz) Fusing Considerations CAUTION: This power module is not internally fused. An input line fuse must always be used. ...

Page 3

... Output Short-circuit Current (V = 1.0 V; indefinite duration, no hiccup mode) O Efficiency ( max see Figure 10.): FW250C1 FW300C1 Switching Frequency Dynamic Response (ΔI /Δ A/10 µ with a 10 µF aluminum and a 1.0 µF ceramic capacitor across the load; see Figures 5 and 6.): Load Change from I = 50 ...

Page 4

... Min Typ Max 0 — 1.2 — — 1.0 — — 15 — — 50 — — — — 0.5 60 — 100 17.0* — 20.0* — 0.25 — Lineage Power Unit pF MΩ Unit hours g (oz.) Unit µ set nom V V/A ...

Page 5

... For guidance on appropriate soldering, cleaning, and drying procedures, refer to the Board-Mounted Power Modules Soldering and Cleaning Application Note (AP97-021EPS). Lineage Power Symbol Min Typ — ...

Page 6

... OUTPUT CURRENT, I Figure 2. Typical FW300C1 Output Characteristics at Room Temperature OUT OUT OUT (V) I 8-2141 (F) Figure 3. Typical FW300C1 Efficiency vs. Output = Full Load = (A) O 8-2142 (F) Note: See Figure 10 for test conditions. Figure 4. Typical FW300C1 Output Ripple Voltage OUTPUT CURRENT, I (A) O Current at Room Temperature ...

Page 7

... Figure 6. Typical FW300C1 Transient Response to Step Increase in Load from 50% to 75% of Full Load at Room Temperature and 48 V Input (Waveform Averaged to Eliminate Ripple Component.) Lineage Power 15 V Figure 7. Typical FW300C1 Start-Up Transient at 8-2145 (F) Room Temperature Input, and Full Load 8-2146 (F) TIME ms/div) 8-2147 (F) ...

Page 8

... The power module has extra-low voltage (ELV) outputs when all inputs are ELV. The input to these units provided with a maxi- mum 20 A normal-blow fuse in the ungrounded lead. % April 2008 pin and one V pin are to be grounded Lineage Power ...

Page 9

... V (–) I Figure 11. Remote On/Off Implementation Lineage Power Remote Sense Remote sense minimizes the effects of distribution losses by regulating the voltage at the remote-sense connections. The voltage between the remote-sense pins and the output terminals must not exceed the out- put voltage sense range given in the Feature Specifica- tions table, i ...

Page 10

... I Figure 13. Circuit Configuration to Decrease 1M 100k (+) and O 10k ) 2Δ% + ⎞ kΩ 1k ⎠ Δ% 0 Figure 14. Resistor Selection for Decreased Output April 2008 V (+) O SENSE(+) TRIM R adj-down SENSE(–) V (–) O Output Voltage CHANGE IN OUTPUT VOLTAGE (Δ%) Voltage Lineage Power R LOAD 8-748 (F).b 40 8-1171 (F).g ...

Page 11

... Lineage Power Output Current Monitor The CURRENT MON pin provides a dc voltage propor- tional to the dc output current of the module given in the Feature Specifications table. For example, on the FW250C1, the V/A ratio is set at 250 mV/A ± ...

Page 12

... This external volt- age level must not exceed 40 V, and the current into the PWR GOOD pin during the low-impedance state should be limited maximum. April 2008 SENSE(+) SENSE(–) V (+) O V (–) O SENSE(+) SENSE(–) V (+) O V (–) O 8-581 (F) Lineage Power ...

Page 13

... Derating curves for forced-air cooling without a heat sink are shown in Figures 19 and 20. These curves can be used to determine the appropriate airflow for a given set of operating conditions. For example, if the unit with airflow along its length dissipates heat, the correct airflow °C environment is 1.0 m/s (200 ft./min.). Lineage Power ...

Page 14

... To choose a heat sink, determine the power dissipated 1 1/2 IN. HEAT SINK as heat by the unit for the particular application. 1 IN. HEAT SINK Figure 23 shows typical heat dissipation for a range of 1/2 IN. HEAT SINK 1/4 IN. HEAT SINK output currents and three voltages for the FW300C1. NO HEAT SINK ...

Page 15

... Thermal Considerations Heat Transfer with Heat Sinks Example °C case temperature is desired, what is the minimum airflow necessary? Assume the FW300C1 module is operating at nominal line and an output cur- rent maximum ambient air temperature of 40 °C, and the heat sink is 1/2 inch. Solution ...

Page 16

... DIA SOLDER-PLATED BRASS, 11 PLACES, (VOUT–, VOUT+, VIN–, VIN+) MOUNTING INSERTS M3 x 0.5 THROUGH, 4 PLACES 5.1 (0.20) 10.16 (0.400) 15.24 30.48 (0.600) VO– (1.200) 5.08 20.32 (0.800) (0.200) 25.40 (1.000) 35.56 (1.400) VO+ 8-1650 (F).pg1 Lineage Power ...

Page 17

... TYP VO– VO+ 106.68 (4.200) Output Power 250 W 300 W 7.62 12.7 (0.300) (0.50) 7.62 (0.300) CASE 12.70 SYNC OUT (0.500) 17.78 (0.700) SYNC IN 22.86 ON/OFF (0.900) 30.48 VI– (1.200) 50.8 VI+ (2.00) 5.1 (0.20) 8-1650 (F).pg2 Device Code Comcode FW250C1 107588345 FW300C1 107588352 17 ...

Page 18

... Figure 25. Longitudinal Heat Sink 18 18 1/4 IN. 1/2 IN. 1 IN. 1 1/2 IN. 8-2830 (F) April 2008 Comcode 847308335 847308327 847308350 847308343 847308376 847308368 847308392 847308384 1/4 IN. 59.94 1/2 IN. (2.36) 1 IN. 115.82 (4.56) 1 1/2 IN. Figure 26. Transverse Heat Sink Lineage Power 8-2831 (F) ...

Page 19

... April 2008 dc-dc Converters Vdc Input, 15 Vdc Output; 250 W to 300 W Notes Lineage Power 19 ...

Page 20

... Lineage Power reserves the right to make changes to the produc t(s) or information contained herein without notice. No liability is ass umed as a res ult of their use or applic ation. No rights under any patent acc ompany the sale of any oduct information. ...