AXA003A0X4Z Lineage Power, AXA003A0X4Z Datasheet - Page 2

CONVERT DC/DC 0.75 5.5V @ 3A SIP

AXA003A0X4Z

Manufacturer Part Number
AXA003A0X4Z
Description
CONVERT DC/DC 0.75 5.5V @ 3A SIP
Manufacturer
Lineage Power
Series
Austin MiniLynx™r
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheet

Specifications of AXA003A0X4Z

Output
0.75 ~ 5.5V
Number Of Outputs
1
Power (watts)
16W
Mounting Type
Through Hole
Voltage - Input
8.3 ~ 14V
Package / Case
5-SIP Module
1st Output
0.75 ~ 5.5 VDC @ 3A
Size / Dimension
0.90" L x 0.26" W x 0.40" H (22.9mm x 6.6mm x 10.2mm)
Power (watts) - Rated
16.5W
Operating Temperature
-40°C ~ 85°C
Efficiency
91%
Approvals
CSA, EN, UL, VDE
Output Power
17 W
Input Voltage Range
8.3 V to 14 V
Output Voltage (channel 1)
0.75 V to 5.5 V
Output Current (channel 1)
3 A
Package / Case Size
SIP
Output Type
Non-Isolated
Output Voltage
0.75 V to 5.5 V
Product
Non-Isolated / POL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
555-1052
CC109104824
Data Sheet
October 2, 2009
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being
part of a complex power architecture. To preserve maximum flexibility, internal fusing is not included, however, to
achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-
acting fuse with a maximum rating of 6 A (see Safety Considerations section). Based on the information provided in
this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be
used. Refer to the fuse manufacturer’s data sheet for further information.
LINEAGE
Parameter
Input Voltage
Operating Ambient Temperature
Storage Temperature
Parameter
Operating Input Voltage
Maximum Input Current
(V
Input No Load Current
Input Stand-by Current
Inrush Transient
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V
V
Input Ripple Rejection (120Hz)
IN, max,
Continuous
(see Thermal Considerations section)
(V
(V
IN
= V
IN
IN
= V
= V
IN, min
I
O
= I
IN, nom
IN, nom
POWER
Omax
to V
, module disabled)
Vdc, I
; See Test configuration section)
IN, max
O
, I
= 0, module enabled)
O
=I
O, max
V
O,set
= 3.3Vdc)
8.3 – 14Vdc Input; 0.75Vdc to 5.5Vdc Output; 3A output current
IN, min
to
Austin MiniLynx
V
V
O,set
V
V
O,set
o,set
o,set
Device
= 0.75Vdc
= 5.5Vdc
All
All
All
All
All
> 3.63
≤ 3.63
Device
All
All
All
TM
Symbol
I
I
I
IN,stand-by
IN,No load
IN,No load
12V SIP Non-isolated Power Modules:
I
IN,max
V
V
I
2
Symbol
IN
IN
t
T
V
T
stg
IN
A
Min
8.3
8.3
-0.3
Min
-40
-55
Typ
150
1.2
12
12
45
30
30
Max
125
15
85
Max
13.2
2.2
0.4
14
mAp-p
Unit
Vdc
°C
°C
Unit
Vdc
Vdc
Adc
A
mA
mA
mA
dB
2
s
2

Related parts for AXA003A0X4Z