... Point-of-Load (POL) power modules, are the latest offerings from a world leader in power systems technology and manufacturing -- Delta Electronics, Inc. This product family provides output current or 20W of output power in an industry standard, compact, IC-like, molded package highly integrated and does not require external components to provide the point-of-load function ...
Page 2
TECHICAL SPECIFICATIONS T = 25°C, airflow rate = 300 LFM 12Vdc, nominal Vout unless otherwise noted PARAMETER ABSOLUTE MAXIMUM RATINGS Input Voltage (Continuous) Operating Temperature Storage Temperature INPUT CHARACTERISTICS Operating Input Voltage Input Under-Voltage Lockout Turn-On ...
Page 3
ELECTRICAL CHARACTERISTICS CURVES LOAD (A) Figure 1: Converter efficiency vs. output current (0.90V output voltage LOAD (A) Figure 3: Converter efficiency vs. output current (1.5V ...
Page 4
ELECTRICAL CHARACTERISTICS CURVES 100 LOAD (A) Figure 7: Converter efficiency vs. output current (5.0V output voltage) Figure 9: Output ripple & noise at 12Vin, 1.2V/4A out Figure 11: Output ripple & noise at ...
Page 5
ELECTRICAL CHARACTERISTICS CURVES Figure 13: Output ripple & noise at 12Vin, 3.3V/4A out Figure 15: Power on waveform at 12vin, 0.9V/4A out with application of Vin Figure 17: Power off waveform at 12vin, 0.9V/4A out with application of Vin DS_IPM12C0A0R04_03202007 ...
Page 6
ELECTRICAL CHARACTERISTICS CURVES Figure 19: Remote turn on delay time at 12vin, 0.9V/4A out Figure 21: Turn on delay at 12vin, 0.9V/4A out with application of Vin Figure 23: Typical transient response to step load change at 2.5A/µS from 100% ...
Page 7
TEST CONFIGURATIONS TO OSCILLOSCOPE L 2 47uF BATTERY Tantalum Note: Input reflected-ripple current is measured with a simulated source inductance. measured at the input of the module. Figure 25: Input reflected-ripple current test setup COPPER STRIP Vo 10uF 1uF SCOPE ...
Page 8
DESIGN CONSIDERATIONS Safety Considerations For safety-agency approval the power module must be installed in compliance with the spacing and separation requirements of the end-use safety agency standards. For the converter output to be considered meeting the requirements of safety extra-low ...
Page 9
FEATURES DESCRIPTIONS (CON.) For example: to program the output voltage of the IPM module to 3.3Vdc, Rtrim is calculated as follows: 3.752 Rtrim = 3.3 –0.9 Rtrim = 1.302 KΩ IPM can also be programmed by applying a voltage between ...
Page 10
FEATURE DESCRIPTIONS (CON. Table 1 provides Rtrim values required for some common output voltages, while Table 2 provides value of external voltage source, Vtrim, for the same common output voltages. By using a 0.5% tolerance resistor, set point tolerance of ...
Page 11
THERMAL CONSIDERATIONS Thermal management is an important part of the system design. To ensure proper, reliable operation, sufficient cooling of the power module is needed over the entire temperature range of the module. Convection cooling is usually the dominant mode ...
Page 12
THERMAL CURVES (CON.) IPM12C (Standard) Output Current vs. Ambient Temperature and Air Velocity @ Vin=12V, Vout = 1.8V (Either Orientation) Output Current( Natural Convection Figure 38: Output current vs. ...
Page 13
PICK AND PLACE LOCATION All dimensions are in millimeters (inches) LEAD FREE PROCESS RECOMMEND TEMP. PROFILE Temp. Temp Peak Tem p. 240 ~ 245 Peak Tem p. 240 ~ 245 C C 217 217 ...
Page 14
MECHANICAL DRAWING SMD PACKAGE RECOMMEND PWB PAD LAYOUT Not e: The opper pad is recommended ote: All dimension are in millimeters(inches) standard dimension tolerance is DS_IPM12C0A0R04_03202007 SIP PACKAGE connect to ...
Page 15
... Family Voltage Outputs Integrated POL 14V C – Low current Module MODEL LIST Model Name Packaging IPM12C0A0R04FA SIP IPM12C0A0S04FA SMD IPM04C0A0R06FA SIP IPM04C0A0S06FA SMD CONTACT: www.delta.com.tw/dcdc USA: Telephone: East Coast: (888) 335 8201 West Coast: (888) 335 8208 Fax: (978) 656 3964 Email: DCDC@delta-corp ...