S8VS-06024B Omron, S8VS-06024B Datasheet - Page 21

POWER SUPPLY W/DISP 24VDC 2.5A

S8VS-06024B

Manufacturer Part Number
S8VS-06024B
Description
POWER SUPPLY W/DISP 24VDC 2.5A
Manufacturer
Omron
Series
S8VSr
Datasheets

Specifications of S8VS-06024B

Power Supply Type
Switching (Closed Frame)
Voltage - Output
24V
Number Of Outputs
1
Power (watts)
60W
Applications
Commercial
Voltage - Input
85 ~ 264VAC
Mounting Type
DIN Rail
1st Output
24 VDC @ 2.5A
Size / Dimension
4.26" L x 1.57" W x 3.74" H (108.3mm x 40mm x 95mm)
Power (watts) - Rated
60W
Operating Temperature
-10°C ~ 60°C
Efficiency
78%
Approvals
CE, CSA, cUL, EN, UL, VDE
Product
Switching
Output Power Rating
60 W
Output Voltage (channel 1)
24 V
Output Current (channel 1)
2.5 A
Dimensions
108.3 mm L x 40 mm W x 95 mm H
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
24V
Output Current
2.5A
Power Rating
60W
Input Voltage
85V AC To 264V AC
Length
108.3mm
Width
40mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
S8VS06024B
Z1667
Maintenance Forecast (S8VS-@@@24A@@)
Displays when the maintenance forecast has reached the set value.
Operation
Mode
Maintenance
forecast
monitor
Output
voltage
Output
current
Peak-hold
current
The maintenance forecast
has reached the set value.
(See note.)
Note: This indicator alternately
displays alarm (
and the maintenance
time until replacement.
Remaining time
until replacement
)
Indication and Output
When the Product is purchased, “
electrolytic capacitors deteriorate, indication changes to “
to page 22). “
display for approximately one month after the Power Supply is first
turned ON. The accumulated value will then be displayed depending
on the ambient conditions thereafter. (However, the “
may not appear, depending on the usage environment and the set
value for maintenance forecast.)
S8VS-06024A:
After the remaining time to maintenance is reduced to less than two
years, indication automatically changes to a value, which decreases
from “
increase. If the remaining time becomes less than 0.5 year, an alarm
(
S8VS-09024A@@/S8VS-12024A@,
S8VS-18024A@/S8VS-24024A@/S8VS-48024A:
If the maintenance forecast setting L (which can be set arbitrarily from
0.0 to 5.0 years in 0.5-year steps) is set to a value larger than two
years, the indication automatically changes to a value (L - 0.5) after
the remaining time to maintenance is reduced to the set years, and an
alarm (
If the setting is less than 2.0 years, the indication changes to a value
(1.5) after the remaining time becomes less than two years, and after
the remaining time becomes less than the set time, an alarm (
and the remaining time (L - 0.5) are indicated alternately.
If the alarm (
transistor (maintenance forecast output terminal (Yrs)) will turn OFF
to indicate the need for maintenance. (The transistor turns OFF when
the maintenance forecast time is reached, i.e., there will be no
continuity at the maintenance forecast output terminal.)
Note: 1. The remaining time to maintenance is based on continuous
a02
) and “
1.5
2. “
3. For details on the display, refer to Relationship between
a02
” to “
operation, not including the time when the power supply is
turned OFF.
time is accumulated to estimate the speed of deterioration
and the output will remain ON (continuity at the
maintenance forecast output terminal (Yrs)).
Indicated Values and Output of Set Values under
Maintenance Forecast Monitor Function on page 22.
ful
) and the remaining time are indicated alternately.
0.0
a02
ful
1.0
” are indicated alternately.
” will be indicated until approximately one month of
) and a numeric value are indicated alternately, a
” to “
” will be indicated for the maintenance forecast
0.5
” to “
0.0
ful
” (year) as the running hours
” will be indicated. As
In the case that the
remaining time is
reduced to smaller
than 0.5 year and an
alarm is issued.
hlf
hlf
” indication
S8VS
” (Refer
a02
)
21